Granular Ice Technical Service Manual
21
COD: IQ02_404MTIN.DOC
4.5. Electrical connection
• Unit is provided with a 1.5 m cord and Schucko socket (except for models GR 560).
• A switch and adequate fuses should be installed. Nominal voltage and intensity are indicated
on rating plate as well as on this manual's technical pages. Voltage fluctuations greater than
10% can cause problems or prevent machine from starting.
• Line to base of plug must have a minimum section=2.5 mm2 for models up to GR 220 and 4
mm2 for other models.
• Be sure voltage indicated on rating plate corresponds to that of mains supply.
IMPORTANT!
Supply socket must be properly earthed. Be sure to check standard for country where appliance
is going to be installed.
4.6. Assembling the dispersión one
This device spreads ice evenly so it does not pile up
beneath exit tube. Its position can be altered to
redirect ice, and hence prevent the “pyramid effect
”.