ELEVATION SERIES CIM CUBERS
SEQUENCE OF OPERATIONS
16
CONTROL BOARD - FREEZE
The Water Pump is energized (R6 LED on Board illuminated) and water is pushed through the Water
Pump Tube and flows over the Evaporator. The High Float Switch contacts close as the water level in the
Sump drops (High Float Switch LED on Board illuminates).
BROWN
BLUE
VIOLET
BLACK
RED
TAN
PINK
YELLOW
= Illuminated LED
WHITE
WHITE
BLUE w/ WHITE
BLUE w/ RED
BLUE
12V DC Switches
Line Voltage
Components
R1
R2
R3
R4
R5
R6