ELEVATION SERIES
ELECTRICAL AND PLUMBING REQUIREMENTS
9
48” CIM SERIES Common Connections
(CIM**4* A)
Air Cooled
Please note: air-cooled units require 6”(152mm) for air intake and exhaust.
(CIM**4* W/R)
Water/Remote Cooled
A. Ice maker potable water in,
3/8” FPT.
B. Ice maker water out,
3/4” FPT.
C. Hole for electrical connections,
7/8”.
D. Electrical junction box,
7/8”.
A. Ice maker potable water in,
3/8” FPT.
B. Ice maker water out,
3/4” FPT.
C. Hole for electrical connections,
7/8”.
D. Electrical junction box,
7/8” (remote).
E. Condenser water in, 3/8” FPT (water only).
Discharge line, 1/2” male quick connect
coupling for pre-charged line set (remote only).
F. Condenser water out,
3/4” FPT (water only).
G. Liquid Line,
3/8” male quick connect coupling for
pre-charged line set (remote only).
Summary of Contents for CIM Series
Page 31: ...ELEVATION SERIES CIM CUBERS BOARD COMPONENT LED SEQUENCE 29 INITIAL HARVEST CYCLE AT START UP ...
Page 32: ...ELEVATION SERIES CIM CUBERS BOARD COMPONENT LED SEQUENCE 30 TRANSITION FROM HARVEST TO FREEZE ...
Page 33: ...ELEVATION SERIES CIM CUBERS BOARD COMPONENT LED SEQUENCE 31 BIN FULL CURTAIN OR STAT ...
Page 35: ...ELEVATION SERIES CIM CUBERS BOARD COMPONENT LED SEQUENCE 33 DIAGNOSTICS IN HARVEST CYCLE ...
Page 36: ...ELEVATION SERIES CIM CUBERS BUTTON FUNCTIONS 34 Button Functions ...