38
Autonomous Hard Floor Scrubber Cobi 18
User Manual
Navigation System
Issue
Solution
Machine stops route
early and returns to
Home Location Code.
1. Ensure working environment is not too narrow and there are not any new obstacles.
Remove new obstacles as needed.
2. Teach new route if necessary.
3. Please contact ICE Cobotics customer service if issue continues to exist.
Machine bypasses
some of the cleaning
route.
1. Check and ensure sensors are positioned correctly.
2. Check and ensure the environment does not exceed a 2 degree slope.
3. Check and ensure machine posture does not have significant changes.
4. Check whether the traction wheels wear is consistent.
5. Please contact ICE Cobotics customer service if issue continues to exist.
Machine not moving
in straight line.
1. Check and ensure lidar is not damaged and is in the correct position.
2. Check and ensure the traction wheels move freely and and are in good working
condition.
3. Please contact ICE Cobotics customer service if issue continues to exist.
Main display screen
shut down.
1. Check and ensure battery is charged. Recharge if necessary.
2. Check for any loose cables.
3. Please contact ICE Cobotics customer service if issue continues to exist.
Route creation
failed.
1. Please try to retrain new route.
2. Home location code may have moved while creating route.
3. Ensure there are no new obstructions such as glass or mirrors in the cleaning path.
Remove as needed.
4. Please contact ICE Cobotics customer service if issue continues to exist.
Self-check failure.
Reboot machine and contact ICE Cobotics customer service if issue continues to exist.
Troubleshooting the Navigation System