Features 

 

 

PC - Radio station 

ISM-usb

 with USB - interface for communication with up to  

120 radio modules 

 

 

Radio modules 

ISM-232 

/   IBRit-rf1-232

 

for gauges with RS232 interface 

  

( for connection

 

ISM-cab1 

/   IBRit-rf1-cab1

 

for connection to gauges via cable,  

 

to gauge )

 

 

 

 

can be adapted to various interfaces 

 

 

ISM-mahr 

/   IBRit-rf1-mahr

 

for gauges with MarConnect interface 

 

 

ISM-mit1 

/   IBRit-rf1-mit1

 

for gauges with Mitutoyo Digimatic interface 

 

 

ISM-opto 

/   IBRit-rf1-opto

 

for gauges with Opto-RS232 interface 

 

 

ISM-prox 

/   IBRit-rf1-prox

 

for gauges with Proximity interface 

 

 

ISM-S233 

/   IBRit-rf1-S233

 

for gauges with Power-RS interface 

 

 

ISM-3i 

 

for gauges with TRIPLE-I interface 

 

 

ISM-ISi 

 

for IMS measuring probes 

 

 

 

    

IBRit-rf1-digi

 

for gauges with Mitutoyo Digimatic interface  

 

 

In the following the IBRit-rf1 and ISM rad

io module are referred to as “gauge radio modules”.

 

 

 

High data security by double and independent check sum control

 

 

 

Optical and acoustical transmission confirmation by the radio modules 

 

 

Radio range of the ISM-usb.1 up to 300 m in case of visual contact ( with external antenna ) 

 

    

1.3    Technical data 

Mechanical  characteristics ISM-usb.1 

 

Case         

 

Plastic

 

Wall holder 

Wall holder for 

ISM-usb

 with two mounting holes 

Dimensions with antenna W x H x D / Weight 

47 x 275 x 30 mm / ca. 175 g 

 

Mechanical  characteristics ISM-usb.2 

 

Case         

 

Plastic

 

Dimensions with antenna W x H x D / Weight 

20.3 x 52.5 x 45.5 mm / ca. 20 g 

 

Electrical characteristics* 

 

Power supply 

By USB - interface 

Current consumption 

max. 40 mA 

Transmission frequency 

433.926 MHz 

Frequency deviation 

± 13 kHz / ± 115.2 kHz 

Modulation type 

FSK 

RF Output power @ 50Ω 

+6 dBm 

Sensitivity @ 50Ω 

-100 dBm 

Transmission speed 

9600 baud / 230400 baud 

* : at an ambient temperature of 25°C. All values are typical values unless otherwise specified. 

 

Environmental conditions 

 

Operating temperature range 

0 ... 50°C 

Storage temperature range 

-30 ... +60°C 

Protection class 

IP50 ( CEI / IEC 529 ) 

 

Specific standards 

 

CE conformity 

Harmonised standard EN 300 220 

FCC 

FCC ID : T6T-604001 

Summary of Contents for ISM-usb.1

Page 1: ...I n t e r f a c e t e c h n o l o g y Document No D2F620 010 Edition April 2020 Copyright IBR Messtechnik GmbH Co KG INSTRUCTION MANUAL ISM usb 1 2 PC Radio station for wireless data transmission...

Page 2: ...d initial operation of the IBR_SimKey PC software 6 3 Programming of gauge radio modules by using the IBR_SimKey PC software 9 4 Confirmation signals of the gauge radio modules 14 5 Signal strength me...

Page 3: ...value changes The radio module completes the measured value by adding an address number sender a communication control word and a double checksum The special data coding and the PC s reply directly to...

Page 4: ...d independent check sum control Optical and acoustical transmission confirmation by the radio modules Radio range of the ISM usb 1 up to 300 m in case of visual contact with external antenna 1 3 Techn...

Page 5: ...2 2 System requirements PC with USB interface and operating system Windows 2000 Windows 10 2 3 Installation of the USB driver for the ISM usb PC Radio station The driver installation package is locate...

Page 6: ...imKey_Inst exe c Follow the instructions displayed in the windows of the programme installer 2 Starting IBR_SimKey Initial operation of the software can take place directly after completion of the ins...

Page 7: ...e or in case there was no PC connection selected in the software you will receive the following message Please confirm the message box by clicking the OK button Now the window for interface settings a...

Page 8: ...the on off button of the radio module concerned The button is located directly on the right hand side of the Gauge Sensor column This programming possibility allows simultaneous operation of several...

Page 9: ...indow for interface settings and instrument selection Quit Closes the IBR_SimKey software Please note that there must be a ISM usb PC Radio station connected to the PC in order to operate the IBR_SimK...

Page 10: ...re to be transmitted automatically in the Permanent Mode The Permanent Mode is started by pressing the data key on the radio module Note Using the Permanent Mode can reduce the lifetime of the module...

Page 11: ...request of the gauge radio modules with Opto RS232 interface Any character or a Simplex Impulse can be set for measurement data request Please refer to the manual of your gauge in order to find the c...

Page 12: ...anent Mode can be used Disadvantages of the 230400 Baud data rate a not IBRit rf1 compatible b only approximately 60 range in comparison with 9600 Baud Please note that the change of the data transmis...

Page 13: ...ion of the measuring values The maximum data rate should not exceed 2 Hz for the mentioned radio modules because else the battery life will be shortened too much The ISM ISi always works with 10 Hz 0...

Page 14: ...by the ISM ISi 4 Confirmation signals of the gauge radio modules The gauge radio modules always return a clear optical and acoustical confirmation to the operator on programming or measurement data t...

Page 15: ...Strength Indicator By this the signal strength of radio or interference signals can be measured which might exist in the frequency range of the ISM or IBRit rf1 radio modules Please use the latest ve...

Page 16: ...ferences The example above shows the background noise on all frequencies and a weak signal at about 434 4 MHz Both will in this strength not influence the receiving of values from the ISM or IBRit rf1...

Page 17: ...which contain the risk that SYSTEMERRORS can lead to damages or personal inju ries should not only depend on electronic systems In order to avoid damages injuries or death the operator or system devel...

Page 18: ...ering with the device shall void the guarantee and exempt the manufacturer from any liability Before opening the instrument make sure to effectively cut the power supply e g by disconnecting the power...

Page 19: ...allation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications H...

Page 20: ...or damage due to Disregard of operating instructions Incorrect handling Tampering by unauthorised staff Attempts by any unauthorised person to repair the instrument We are not to be held liable for an...

Reviews: