Figure 41. Library in the rack
Important: Each module must be on its own rails.
5. With a Phillips screwdriver, loosely screw the module to the front of the rack, one screw on each side.
See the circled areas in Figure 41 on page 49.
6. Align the module as needed. Then, tighten the screws on each side of the module. See “Aligning and
connecting modules” on page 49.
7. Repeat steps 2 - 6 to install the rest of the modules into the rack.
Installing a tabletop module
Installation of a one module library (Base Module only) can be completed without special hardware.
If you unpacked a Table Top Module, confirm that you received the following components:
1. Base Module
2. Accessory Kit
• One North American power cord
• One European power cord
1. Remove the Base Module from the box.
2. Open the cover and remove the foam packing from inside the enclosure. See “Unpacking the Base
Module and Expansion Modules” on page 38.
3. Replace the cover.
4. Set the Base Module in the wanted location. Ensure that it is level.
5. Plug in the power cord and the connecting cables.
Aligning and connecting modules
Aligning the modules ensures that the accessor can move freely between the modules.
Skip this step if the library does not have Expansion Modules.
Aligning the modules ensures that the accessor can move freely between the modules. The library cannot
operate unless the alignment mechanisms of the upper modules are in the locked position, and the
alignment mechanism of the lowest module is unlocked.
Chapter 3. Installing 49
Summary of Contents for TS4300 3555
Page 1: ...IBM TS4300 Tape Library Machine Type 3555 User s Guide IBM SC27 4629 07...
Page 66: ...Chapter 3 Installing 36 IBM TS4300 Tape Library Machine Type 3555 User s Guide...
Page 77: ...Figure 38 Mounting the rails to the connectors Chapter 3 Installing 47...
Page 175: ...Figure 81 Unlocked spooling mechanism enlarged view Chapter 6 Upgrading and servicing 145...
Page 261: ......
Page 262: ...IBM SC27 4629 07...