66
IBM FAStT200 and FAStT200 HA Storage Servers Installation and User’s Guide
One or more green
LEDs off
Power supply CRUs
Power cord
unplugged or
switches turned off
Make sure that the power cord is plugged
in and the power-supply switches are
turned on.
All drive CRUs
Midplane failure
Have the midplane replaced (service
technician only).
Front panel
Power supply
problem
Make sure that the cords are plugged in
and power supplies are turned on.
Hardware failure
If any other LEDs are on, replace the
midplane (service technician only).
Battery
Battery failure
Replace the battery.
Cache active
The cache is
disabled, the cache
has failed, battery
failure
Use the storage-management software to
enable the cache; replace the RAID
controller; replace the battery
Host loop
Host, managed hub,
or switch is off or has
failed
Check if host managed hub or switch is on.
Replace attached devices that have failed.
Fibre Channel cable
has failed
Ensure that the Fibre Channel cables are
undamaged and properly connected.
GBIC has failed
Ensure GBIC is seated properly; replace
GBIC
RAID controller has
no power or has
failed
Ensure that the unit is powered on.
Replace RAID controller
Expansion loop
Drives are improperly
installed or not
installed
Ensure that the drives are properly
installed.
RAID controller has
no power or has
failed
Ensure that the unit is powered on.
Replace the RAID controller.
3542 drive failure
Replace the drive.
Externally attached
expansion port
device has failed
Replace the drive; replace the expansion
unit GBIC or Fiber Channel cable
Intermittent or
sporadic power loss
to the storage server
Some or all CRUs
Defective ac power
source or partially
plugged-in power
cord
Check the ac power source. Reseat all
installed power cables and power supplies.
If applicable, check the power
components. Replace defective power
cords.
Power supply has
failed
Check for a Fault LED on the power
supply, and replace the failed CRU.
Midplane has failed
Have the midplane replaced (service
technician only).
Unable to access
drives
Drives and Fibre
Channel loop
Fibre Channel
cabling has failed.
Ensure that the Fibre Channel cables are
undamaged and properly connected.
RAID controller has
failed
Replace the RAID controller.
GBIC has failed
Ensure GBIC is seated properly; replace
GBIC
Table 7. Storage server troubleshooting
Problem indicator
Component
Possible cause
Possible solutions
Summary of Contents for TotalStorage FAStT200
Page 1: ...IBM IBM FAStT200 and FAStT200 HA Storage Servers Installation and User s Guide SC21 P877 50 ...
Page 2: ......
Page 3: ...IBM IBM FAStT200 and FAStT200 HA Storage Servers Installation and User s Guide SC21 P877 50 ...
Page 10: ...viii IBM FAStT200 and FAStT200 HA Storage Servers Installation and User s Guide ...
Page 26: ...8 IBM FAStT200 and FAStT200 HA Storage Servers Installation and User s Guide ...
Page 34: ...16 IBM FAStT200 and FAStT200 HA Storage Servers Installation and User s Guide ...
Page 42: ...24 IBM FAStT200 and FAStT200 HA Storage Servers Installation and User s Guide ...
Page 54: ...36 IBM FAStT200 and FAStT200 HA Storage Servers Installation and User s Guide ...
Page 88: ...70 IBM FAStT200 and FAStT200 HA Storage Servers Installation and User s Guide ...
Page 94: ...76 IBM FAStT200 and FAStT200 HA Storage Servers Installation and User s Guide ...
Page 112: ...94 IBM FAStT200 and FAStT200 HA Storage Servers Installation and User s Guide ...
Page 113: ......