The LEDs come on and go off intermittently for approximately 60 seconds or
possibly longer. After this time, you are able to discover the controller through
the DS Storage Manager software.
20. Remove the antistatic protection.
21. Use the DS Storage Manager client Subsystem Management window to check
the status of all components in the storage subsystem.
v
If the controller you replaced or upgraded is online and the DS Storage
Manager client Subsystem Management window indicates normal operation,
go to step 24.
v
If the controller you replaced or upgraded is online and the DS Storage
Manager client Subsystem Management window indicates a problem status,
go to “Troubleshooting the storage subsystem” on page 142.
v
If the controller you replaced or upgraded is offline, go to step 22.
22. If the newly inserted controller is in an offline state, see the DS Storage
Manager client online help for instructions on bringing the controller online.
If necessary, open the DS Storage Manager Subsystem Management window
and place the controller online; select the offline controller and click
Advanced
Recovery
Place controller online
.
23. Verify the state of the LEDs on the newly inserted controller. See “RAID
controller LEDs” on page 145. You can also use the Storage Manager client
Subsystem Management window to identify any new faults. Do any storage
subsystems have a fault (Needs Attention) status?
v
Yes – Select the Recovery Guru toolbar button in the Subsystem
Management window, and complete the recovery procedure. If the problem
persists, contact your IBM service representative.
v
No – Go to step 24.
24. Use the DS Storage Manager client software to print a new storage subsystem
profile.
176