Tables
1. Where to find DS4000, DS5100, and DS5300 installation and configuration procedures . . . . xxiv
2. Features at a glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3. Maximum number of storage expansion enclosures
. . . . . . . . . . . . . . . . . . 9
4. Description of Figure 113 on page 181 . . . . . . . . . . . . . . . . . . . . . . . 13
5. Default IP addresses and subnet masks . . . . . . . . . . . . . . . . . . . . . . 15
6. RAID controller specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 17
7. Minimum controller firmware level required by some options . . . . . . . . . . . . . . . 23
8. DS5100 and DS5300 Storage Subsystem weights
. . . . . . . . . . . . . . . . . . 25
9. DS5100 and DS5300 component weights . . . . . . . . . . . . . . . . . . . . . . 26
10. DS5100 and DS5300 shipping carton dimensions . . . . . . . . . . . . . . . . . . . 26
11. Temperature and humidity requirements . . . . . . . . . . . . . . . . . . . . . . 26
12. DS5100 and DS5300 altitude ranges
. . . . . . . . . . . . . . . . . . . . . . . 27
13. DS5100 and DS5300 power and heat dissipation . . . . . . . . . . . . . . . . . . . 28
14. DS5100 and DS5300 operational vibration specifications . . . . . . . . . . . . . . . . 29
15. DS5100 and DS5300 sound levels . . . . . . . . . . . . . . . . . . . . . . . . 29
16. IBM System Storage DS5100 and DS5300 ac power requirements . . . . . . . . . . . . 29
17. Maximum number of drives per drive channel by enclosure type . . . . . . . . . . . . . 61
18. Number of EXP5060 storage expansion enclosures per port and drive channel (non trunking
cabling) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
19. Number of EXP5060 storage expansion enclosures per port and drive channel (trunking cabling)
74
20. Number of storage expansion enclosures per port and drive channel. . . . . . . . . . . . 74
21. DS5100 and DS5300 drive ports and drive channels. . . . . . . . . . . . . . . . . . 79
22. Description of Figure 51 on page 81. . . . . . . . . . . . . . . . . . . . . . . . 81
23. Cabling for DS5100 and DS5300 storage subsystem with one EXP5060 storage expansion
enclosure without trunking
. . . . . . . . . . . . . . . . . . . . . . . . . . . 85
24. Cabling for DS5100 and DS5300 storage subsystem with two EXP5060 storage expansion
enclosures without trunking . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
25. Cabling for DS5100 and DS5300 storage subsystem with three EXP5060 storage expansion
enclosures without trunking . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
26. Cabling for DS5100 and DS5300 storage subsystem with four EXP5060 storage expansion
enclosures without trunking . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
27. Cabling for DS5100 and DS5300 storage subsystem with eight EXP5060 storage expansion
enclosures without trunking . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
28. Cabling for the first EXP5060 storage expansion enclosure with drive-side trunking . . . . . . 96
29. Cabling for the first EXP5060 storage expansion enclosure with drive-side trunking . . . . . . 97
30. Cabling for the second EXP5060 storage expansion enclosure with drive-side trunking . . . . . 97
31. Cabling for the first EXP5060 storage expansion enclosure with drive-side trunking . . . . . . 98
32. Cabling for the second EXP5060 storage expansion enclosure with drive-side trunking . . . . . 99
33. Cabling for the third EXP5060 storage expansion enclosure with drive-side trunking . . . . . . 99
34. Cabling for the fourth EXP5060 storage expansion enclosure with drive-side trunking
. . . . . 99
35. Cabling for the first EXP5060 storage expansion enclosure with drive-side trunking . . . . . . 101
36. Cabling for the second EXP5060 storage expansion enclosure with drive-side trunking
. . . . 101
37. Cabling for the third EXP5060 storage expansion enclosure with drive-side trunking
. . . . . 101
38. Cabling for the fourth EXP5060 storage expansion enclosure with drive-side trunking . . . . . 101
39. Cabling for five to eight EXP5060s, storage expansion enclosures 1 and 2 with drive-side
trunking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
40. Cabling for five to eight EXP5060s, storage expansion enclosures 3 and 4 with drive-side
trunking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
41. Cabling for five to eight EXP5060s, storage expansion enclosures 5 and 6 with drive-side
trunking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
42. Cabling for five to eight EXP5060s, storage expansion enclosures 7 and 8 with drive-side
trunking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
43. Best practice enclosure ID settings scheme
. . . . . . . . . . . . . . . . . . . . 107
© Copyright IBM Corp. 2009
xxi