Table 17. POST error messages (continued)
Error
code/Symptom
Meaning
FRU/action
00019501
Processor 1 is not functioning 1. Check VRM and processor LEDs
2. VRM 1, VRM 2
3. Processor 1
4. Processor board
5. System board
00019502
Processor 2 is not functioning 1. Check VRM and processor LEDs
2. VRM 2
3. Processor 2
4. System board
00019701
Processor 1 failed BIST
1. Processor 1
2. System board
00019702
Processor 2 failed BIST
1. Processor 2
2. System board
00180100
No room for PCI option ROM 1. Run Configuration/Setup
2. Failing adapter
3. System board
00180200
No more I/O space available
for PCI adapter
1. Run Configuration/Setup
2. Failing adapter
3. System board
00180300
No more memory (above 1
MB for PCI adapter)
1. Run Configuration/Setup
2. Failing adapter
3. System board
00180400
No more memory (below 1
MB for PCI adapter)
1. Move the failing adapter to slot 1 or 2
2. Run Configuration/Setup
3. Failing adapter
4. System board
00180500
PCI-option ROM checksum
error
1. Remove failing PCI card
2. System board
00180600
PCI built-in self-test failure;
PCI-to PCI-bridge error
1. Run Configuration/Setup
2. Move the failing adapter to slot 1 or 2
3. Failing adapter
4. System board
00180700,
00180800
General PCI error
1. System board
2. PCI card
01295085
ECC checking hardware test
error
Processor
01298001
No update data for processor
1
1. Ensure that all processors are the same stepping level
and cache size.
2. Processor 1
96
NAS 200 User’s Reference
Summary of Contents for TotalStorage 201
Page 6: ...vi NAS 200 User s Reference...
Page 8: ...viii NAS 200 User s Reference...
Page 10: ...x NAS 200 User s Reference...
Page 16: ...4 NAS 200 User s Reference...
Page 38: ...26 NAS 200 User s Reference...
Page 46: ...34 NAS 200 User s Reference...
Page 98: ...86 NAS 200 User s Reference...
Page 118: ...106 NAS 200 User s Reference...
Page 136: ...124 NAS 200 User s Reference...
Page 139: ......