v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, System x3755 Type 8877 and 7163,” on page 25 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
BMC log message
Sensor
number
Sensor
type
Action
CPU 3 status
Assertion 01 (Thermal
trip)
92
07
Information only; if the message remains:
1. Make sure that the fans have good airflow and are not
obstructed.
2. Reseat the microprocessor and heat sink.
3. Replace the microprocessor/memory card. See “Removing a
microprocessor/memory card” on page 51 and “Replacing a
microprocessor/memory card” on page 51.
CPU 3 status
Assertion 05
(Configuration error)
92
07
Make sure that the microprocessor/memory card is installed
correctly. See “Removing a microprocessor/memory card” on page
51 and “Replacing a microprocessor/memory card” on page 51.
CPU 3 status
Assertion 07 (Processor
presence detected) or 0A
(Processor automatically
throttled)
92
07
Information only
CPU 3 status
Assertion 08 (Processor
disabled)
92
07
1. Check the DIMM error LEDs on the microprocessor/memory
card.
2. Reseat the microprocessor/memory card. See “Removing a
microprocessor/memory card” on page 51 and “Replacing a
microprocessor/memory card” on page 51.
3. Reseat the microprocessor and heat sink.
4. Replace the microprocessor/memory card. See “Removing a
microprocessor/memory card” on page 51 and “Replacing a
microprocessor/memory card” on page 51.
CPU 4 status
Assertion 01 (Thermal
trip)
93
07
Information only; if the message remains:
1. Make sure that the fans have good airflow and are not
obstructed.
2. Reseat the microprocessor and heat sink.
3. Replace the microprocessor/memory card. See “Removing a
microprocessor/memory card” on page 51 and “Replacing a
microprocessor/memory card” on page 51.
CPU 4 status
Assertion 05
(Configuration error)
93
07
Make sure that the microprocessor/memory card is installed
correctly. See “Removing a microprocessor/memory card” on page
51 and “Replacing a microprocessor/memory card” on page 51.
CPU 4 status
Assertion 07 (Processor
presence detected) or 0A
(Processor automatically
throttled)
93
07
Information only
168
IBM System x3755 Type 8877 and 7163: Problem Determination and Service Guide
Summary of Contents for System x3755Types 7163
Page 1: ...IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 8: ...vi IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 40: ...24 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 52: ...36 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 88: ...72 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 194: ...178 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 204: ...188 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 209: ......
Page 210: ...Part Number 49Y0109 Printed in USA 1P P N 49Y0109...