v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, System x3755 Type 8877 and 7163,” on page 25 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
1962
A drive does not contain a valid boot sector.
1. Make sure that a bootable operating system is
installed.
2. Reseat the hard disk drive.
3. Run the hard disk drive diagnostic test.
4. Check for a valid RAID configuration, if a RAID
configuration is in use.
5. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Hard disk drive
b. SAS backplane
c. (Trained service technician only) I/O board.
See “Removing the I/O board assembly” on
page 68 and “Replacing the I/O board
assembly” on page 69.
d. SAS cables
2400
Video controller test failure.
1. Reseat the video adapter (if installed).
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Video adapter (if installed)
b. (Trained service technician only) I/O board.
See “Removing the I/O board assembly” on
page 68 and “Replacing the I/O board
assembly” on page 69.
2462
Video memory configuration error.
(Trained service technician only) Replace the I/O
board, see “Removing the I/O board assembly” on
page 68 and “Replacing the I/O board assembly” on
page 69.
Chapter 5. Diagnostics
91
Summary of Contents for System x3755Types 7163
Page 1: ...IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 8: ...vi IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 40: ...24 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 52: ...36 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 88: ...72 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 194: ...178 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 204: ...188 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 209: ......
Page 210: ...Part Number 49Y0109 Printed in USA 1P P N 49Y0109...