Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, System x3755 Type 8877 and 7163,” on page 25 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
BMC log message
Sensor
number
Sensor
type
Action
VRD 1.2V
Assertion 01 (Power unit
failure)
2F
08
1. (Trained service technician only) Replace the I/O board, see
“Removing the I/O board assembly” on page 68 and
“Replacing the I/O board assembly” on page 69.
2. Isolate the failing microprocessor/memory card. See
“Removing a microprocessor/memory card” on page 51 and
“Replacing a microprocessor/memory card” on page 51.
3. Replace the microprocessor/memory card. See “Removing a
microprocessor/memory card” on page 51 and “Replacing a
microprocessor/memory card” on page 51.
Ambient temperature
32
01
Make sure that the fans have good airflow and are not obstructed.
Exhaust temperature
33
01
Make sure that the fans have good airflow and are not obstructed.
Power supply 1 fault
38
08
1. Reseat power supply 1.
2. Replace power supply 1.
3. (Trained service technician only) Replace the I/O board, see
“Removing the I/O board assembly” on page 68 and
“Replacing the I/O board assembly” on page 69.
Power supply 2 fault
39
08
1. Reseat power supply 2.
2. Replace power supply 2.
3. (Trained service technician only) Replace the I/O board, see
“Removing the I/O board assembly” on page 68 and
“Replacing the I/O board assembly” on page 69.
Fan 1 tach
40
04
1. Reseat fan 1.
2. Replace fan 1.
3. (Trained service technician only) Replace the I/O board, see
“Removing the I/O board assembly” on page 68 and
“Replacing the I/O board assembly” on page 69.
Fan 2 tach
41
04
1. Reseat fan 2.
2. Replace fan 2.
3. Replace the front fan board.
4. (Trained service technician only) Replace the I/O board, see
“Removing the I/O board assembly” on page 68 and
“Replacing the I/O board assembly” on page 69.
Fan 3 tach
42
04
1. Reseat fan 3.
2. Replace fan 3.
3. Replace the front fan board.
4. (Trained service technician only) Replace the I/O board, see
“Removing the I/O board assembly” on page 68 and
“Replacing the I/O board assembly” on page 69.
162
IBM System x3755 Type 8877 and 7163: Problem Determination and Service Guide
Summary of Contents for System x3755Types 7163
Page 1: ...IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 8: ...vi IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 40: ...24 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 52: ...36 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 88: ...72 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 194: ...178 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 204: ...188 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 209: ......
Page 210: ...Part Number 49Y0109 Printed in USA 1P P N 49Y0109...