v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, System x3755 Type 8877 and 7163,” on page 25 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
5962
IDE CD or DVD drive configuration error.
1. Run the Configuration/Setup Utility program,
select
Load Default Settings
, and save the
settings. See “Starting the Configuration/Setup
Utility program” on page 14
2. Reseat the following components:
a. CD or DVD drive power cable
b. CD or DVD drive IDE cable
c. CD or DVD drive
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. CD or DVD drive power cable
b. CD or DVD drive IDE cable
c. CD or DVD drive
d. (Trained service technician only) I/O board.
See “Removing the I/O board assembly” on
page 68 and “Replacing the I/O board
assembly” on page 69.
e. Battery. See “Removing the battery” on page
53 and “Replacing the battery” on page 54.
8603
Pointing-device error.
1. Reseat the pointing device.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Pointing device
b. (Trained service technician only) I/O board.
See “Removing the I/O board assembly” on
page 68 and “Replacing the I/O board
assembly” on page 69.
92
IBM System x3755 Type 8877 and 7163: Problem Determination and Service Guide
Summary of Contents for System x3755Types 7163
Page 1: ...IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 8: ...vi IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 40: ...24 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 52: ...36 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 88: ...72 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 194: ...178 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 204: ...188 IBM System x3755 Type 8877 and 7163 Problem Determination and Service Guide...
Page 209: ......
Page 210: ...Part Number 49Y0109 Printed in USA 1P P N 49Y0109...