Procedure
1.
From the library's Activity screen, press the PAUSE key. The library displays the
message
If you open the door the library will go Not Ready and any remaining
jobs in the work queue may fail. Press ENTER to continue.
2.
Press ENTER. The message
PAUSE in Progress
displays. The library parks the
cartridge accessor in the base frame and displays the message
The library is now
paused. Normal operations will resume in 30 seconds.
3.
Within 30 seconds, unlock and open the front door on the HD frame. If you do not
open the door within 30 seconds, the Activity screen redisplays and library operations
resume.
CAUTION:
•
HD slots have a constant force spring for pushing
cartridges forward when a cartridge is being removed from the
slot.
•
Only remove cartridges from a frame whose front door
is open. Do not add or remove cartridges from an adjacent frame.
4.
Locate the HD slot containing the cartridges you want to remove and perform the
following procedure:
•
For HD slots in an LTO frame:
a.
. Use the middle finger and thumb on your left hand to
grab the cartridge as shown. Apply outward pressure with the middle finger to
open the cartridge gate assembly as you release and slowly remove the
cartridge as shown in
Figure 1. LTO HD slot gate release