Table 5. Troubleshooting
Problem
indicator
Component
Possible cause
Possible solutions
Amber LED is lit
Drive (drive
fault LED)
Drive failure
Replace the failed drive.
Drive uncertified
Verify the drive and part number
to make sure that it is supported
by the DS3300. (See
http://www.ibm.com/systems/
storage/disk/ds3000/ds3300/.)
RAID controller
(service action
required LED)
RAID controller
failure
Replace the RAID controller. See
Chapter 5, “Replacing
components,” on page 63 for
more information.
The controller was
placed offline by a
user or the other
controller.
Use the Subsystem Management
window to place the controller
back online. If the controller
continues going to an offline state
after being placed online, replace
the RAID controller.
RAID controller
(battery fault
LED)
Battery unit failure
Use the DS3000 Storage
Manager software to confirm the
failure; then, replace the failed
battery unit.
RAID controller
(SAS link
service action
LED)
SAS cable failure
Replace the SAS cable.
SAS host bus
adapter failure
Check the SAS host bus adapter
in the host and replace the
adapter if necessary.
SAS port failure
Replace the controller.
Front bezel
(system error
LED)
General machine
fault
A fault LED is lit somewhere on
the storage subsystem (check for
amber LEDs on components).
General machine
fault (continued)
Open the DS3000 Storage
Manager Subsystem
Management window and click
Recovery Guru
to see problems
in the DS3300 configuration.
Some errors will cause the
system error LED to be lit but will
not cause any individual
component fault LEDs to be lit.
(Drive PFA exceeded or nominal
temperature exceeded errors are
examples.) Follow the corrective
actions in the Recovery Guru
window.
Amber LED is lit
and green LED is
off
Power supply
(fault and
power LEDs
are lit)
The power switch is
turned off or there is
an ac power failure.
Replace the failed power supply
or turn on all power-supply
switches.
96
System Storage DS3300 Storage Subsystem: Installation, User’s, and Maintenance Guide
Summary of Contents for System Storage DS3300
Page 1: ...System Storage DS3300 Storage Subsystem Installation User s and Maintenance Guide...
Page 2: ......
Page 3: ...System Storage DS3300 Storage Subsystem Installation User s and Maintenance Guide...
Page 8: ...vi System Storage DS3300 Storage Subsystem Installation User s and Maintenance Guide...
Page 12: ...x System Storage DS3300 Storage Subsystem Installation User s and Maintenance Guide...
Page 15: ...DANGER Rack mounted devices are not to be used as shelves or work spaces L002 Safety xiii...
Page 40: ...22 System Storage DS3300 Storage Subsystem Installation User s and Maintenance Guide...
Page 60: ...42 System Storage DS3300 Storage Subsystem Installation User s and Maintenance Guide...
Page 80: ...62 System Storage DS3300 Storage Subsystem Installation User s and Maintenance Guide...
Page 118: ...100 System Storage DS3300 Storage Subsystem Installation User s and Maintenance Guide...
Page 139: ......
Page 140: ...Part Number 46M1393 Printed in USA 1P P N 46M1393...