Table 5. Troubleshooting (continued)
Problem
indicator
Component
Possible cause
Possible solutions
Intermittent or
sporadic power
loss to the storage
subsystem
Some or all
components
Defective ac power
source or incorrectly
connected power
cable
Check the ac power source.
Reseat all installed power cords
and power supplies. If applicable,
check the power components
(power-supply units or
uninterruptible power supply).
Replace defective power cords.
Power-supply failure Check the fault LED on the
power supply. If the LED is lit,
replace the failed component.
Midplane failure
Replace the DS3300. Contact
your IBM technical-support
representative.
Unable to access
drives
Drives
Incorrect storage
subsystem ID
settings
Make sure that the SAS cables
are undamaged and correctly
connected. Check the storage
subsystem ID settings.
RAID controller
failure
Replace one or both RAID
controllers. Contact an IBM
technical-support representative.
Drive failure
Replace the failed drive or drives.
Random errors
Subsystem
Midplane failure
Replace the DS3300. Contact
your IBM technical-support
representative.
Hard disk drive is
not visible in the
Storage Manager
software
Several
components
Drive failure
Replace the failed drive or drives.
SAS cable failed
Replace the SAS cable.
RAID controller
failure
Replace RAID controller.
Midplane failure
Replace the DS3300. Contact
your IBM technical-support
representative.
A drive has an
interface problem
with the ESM or
controller.
Replace the drive.
Incorrect firmware
version
Make sure that the DS3300 has
the correct firmware version. See
“Software and hardware
compatibility and upgrades” on
page 11.
In a dual-controller
storage subsystem,
one controller has
failed, and in the
drive channel that
originates from the
other (functioning)
controller, an ESM
has failed.
Replace the failed controller and
ESM.
Chapter 6. Solving problems
99
Summary of Contents for System Storage DS3300
Page 1: ...System Storage DS3300 Storage Subsystem Installation User s and Maintenance Guide...
Page 2: ......
Page 3: ...System Storage DS3300 Storage Subsystem Installation User s and Maintenance Guide...
Page 8: ...vi System Storage DS3300 Storage Subsystem Installation User s and Maintenance Guide...
Page 12: ...x System Storage DS3300 Storage Subsystem Installation User s and Maintenance Guide...
Page 15: ...DANGER Rack mounted devices are not to be used as shelves or work spaces L002 Safety xiii...
Page 40: ...22 System Storage DS3300 Storage Subsystem Installation User s and Maintenance Guide...
Page 60: ...42 System Storage DS3300 Storage Subsystem Installation User s and Maintenance Guide...
Page 80: ...62 System Storage DS3300 Storage Subsystem Installation User s and Maintenance Guide...
Page 118: ...100 System Storage DS3300 Storage Subsystem Installation User s and Maintenance Guide...
Page 139: ......
Page 140: ...Part Number 46M1393 Printed in USA 1P P N 46M1393...