Table 36 on page 95 provides the acoustical specifications for the 2077-92F, 2077-A9F and 2078-92F,
2078-A9F SAS expansion enclosures in accordance with ISO 9296
(1,2,3)
.
Important: Hearing conservation program (HCP) procedures are required for field service personnel
servicing a 2077-92F, 2077-A9F or 2078-92F, 2078-A9F SAS expansion enclosure.
Table 36. Declared noise emissions for 5U SAS expansion enclosures in accordance with ISO 9296
Model and type
Declared A-Weighted Sound Power
Level, L
WAd
(B)
Declared A-Weighted Sound Pressure
Level, L
pAm
(dB)
Operating
Idling
Operating
Idling
Fully configured
expansion
enclosure, MTM /
Model 2077-92F,
2077-A9F
2078-92F, 2078-
A9F
8.5
8.5
85
85
Notes:
1. Declared level L
WAd
is the upper-limit A-weighted sound power level. Declared level L
pAm
is the mean A-
weighted sound pressure level measured at the 1-meter bystander positions.
2. All measurements are made in conformance with ISO 7779 and declared in conformance with ISO 9296.
3. "B" and "dB" are abbreviations for bels and decibels, respectively. 1 B = 10 dB.
Important: Government regulations (such as those prescribed by OSHA or European Community Directives)
may govern noise level exposure in the workplace and may apply to you and your server installation. This
system is available with an optional acoustical door feature that can help reduce the noise emitted from this
system. The actual sound pressure levels in your installation depend upon a variety of factors, including the
number of racks in the installation; the size, materials, and configuration of the room where you designate the
racks to be installed; the noise levels from other equipment; the room ambient temperature, and employees'
location in relation to the equipment. Further, compliance with such government regulations also depends
upon a variety of additional factors, including the duration of employees' exposure and whether employees
wear hearing protection. IBM recommends that you consult with qualified experts in this field to determine
whether you are in compliance with the applicable regulations.
Shock and vibration specifications for Storwize V5100 SAS expansion enclosures
Table 37 on page 95 and Table 38 on page 95 provide the shock and vibration testing results for
Storwize V5100 SAS expansion enclosures.
Table 37. Shock testing results
Shock categories
Test level
Performance
Operational
5 g 10 ms 1/2 Sine
<=25 g 10 ms
Non-operational
30 g 10 ms 1/2 Sine
<=75 g 11 ms
Table 38. Vibration testing results
Vibration
categories
Test level
Performance
Operational
0.21 grms 5-500 Hz Random
Throughput loss <=10% FCAL <= 0.68
grms
Non-operational
1.04 grms 2-200 Hz Random
<=3.12 grms