Acoustical Declaration with Noise Hazard Notice
Figure 85 on page 89 indicates the declared noise emissions values in accordance with ISO 9296.
Figure 85. Acoustical Declaration with Noise Hazard Notice
Shock and vibration specifications for Storwize V5100 enclosures
Table 26 on page 89 and Table 27 on page 89 provide the shock and vibration testing results for your
Storwize V5100 system.
Table 26. Shock testing results
Shock categories
Test level
Performance
Operational
5 g 10 ms 1/2 Sine
<=25 g 10 ms
Non-operational
30 g 10 ms 1/2 Sine
<=75 g 11 ms
Table 27. Vibration testing results
Vibration categories
Test level
Performance
Operational
0.21 grms 5-500 Hz Random
Throughput loss <=10% FCAL <= 0.68 grms
Non-operational
1.04 grms 2-200 Hz Random
<=3.12 grms
Shipping
0.3 g 2-200 Hz Sine
<=5 g
Rotational vibration
Normal operation performance
measurements in enclosure with
no external vibration.
Throughput loss for all drives of the same type
within performance profile.
Appendix C. Control enclosure requirements 89
Summary of Contents for Storwize V5100 Series
Page 129: ......