Note:
This unit is intended for installation in restricted access areas. A restricted
access area can be accessed only by using a special tool, lock and key, or other
means of security.
Note:
Only trained and qualified personnel should be allowed to install, replace,
or service this equipment.
Note:
Before you install, operate, or service the system, see the IBM Systems Safety
Notices for important safety information.
Use this procedure to install the switch on top of the rack-mount support brackets.
Procedure
1.
Verify that the rack-mount support brackets are level and securely attached to
the rack-mounting rails, the support rack-mount support brace is securely
attached to the brackets, and the rack is stabilized.
2.
Slide a mechanical lift under the switch and lift the switch up onto the
rack-mount support brackets, ensuring it is squarely positioned.
3.
Attach the switch to the rack-mounting rails. See the “Required Equipment” on
page 45.
CAUTION:
We recommend grounding the chassis, even if the rack is already grounded.
There is a grounding pad with two threaded M4 holes on the chassis for
attaching a grounding lug.
Installing the Switch on the Shelf Brackets
This section provides general instructions for installing the switch on top of the
shelf brackets.
About this task
For detailed information about the items required for installation, see the
“Required Equipment” on page 45.
The IBM c-type SAN Director Shelf Bracket Kit can be used to support the switch
in a non-threaded rack. This shelf bracket kit can be used as a permanent support
when installing a IBM c-type SAN Director in a rack that meets the requirements
listed in the “Rack Requirements” on page 41.
Note:
This unit is intended for installation in restricted access areas. A restricted
access area can be accessed only by using a special tool, lock and key, or other
means of security.
Note:
Only trained and qualified personnel should be allowed to install, replace,
or service this equipment.
Note:
Before you install, operate, or service the system, see the IBM Systems Safety
Notices for important safety information.
Use this procedure to install the switch on top of the shelf brackets.
Procedure
1.
Verify that the shelf brackets are level and securely attached to the
rack-mounting rails, the crossbar is securely attached to the shelf brackets, and
the rack is stabilized.
Chapter 2. Rack Installation
47
Summary of Contents for SAN192C-6
Page 2: ......
Page 8: ...vi SAN192C 6 SAN384C 6 and SAN768C 6 Installation Service and User Guide ...
Page 10: ...viii SAN192C 6 SAN384C 6 and SAN768C 6 Installation Service and User Guide ...
Page 24: ...xxii SAN192C 6 SAN384C 6 and SAN768C 6 Installation Service and User Guide ...
Page 114: ...90 SAN192C 6 SAN384C 6 and SAN768C 6 Installation Service and User Guide ...
Page 122: ...98 SAN192C 6 SAN384C 6 and SAN768C 6 Installation Service and User Guide ...
Page 143: ...Figure 47 AJK2 Figure 48 AJK1 Figure 49 AJJY Appendix B Cable and Port Specifications 119 ...
Page 144: ...Figure 50 AJJV 120 SAN192C 6 SAN384C 6 and SAN768C 6 Installation Service and User Guide ...
Page 146: ...122 SAN192C 6 SAN384C 6 and SAN768C 6 Installation Service and User Guide ...
Page 158: ...134 SAN192C 6 SAN384C 6 and SAN768C 6 Installation Service and User Guide ...
Page 159: ......
Page 160: ...IBM Part Number 02JD693 Printed in USA SC27 9276 00 1P P N 02JD693 ...