Verifying Installation of the Supervisor and Switching Modules
About this task
To verify the module installation, complete the following steps:
Procedure
1.
Verify that the ejector levers of each module are fully closed (parallel to the
front of the module) to ensure that the supervisor module and all switching or
services modules are fully seated in the backplane connectors.
2.
Check the captive screws of each module, the power supply, and the fan
module. Tighten any loose captive screws to 8 in-lb.
3.
Verify that any empty module slots have filler panels installed and that the
screws holding the panels in place are tight.
4.
Turn on the power supply switches to power up the system and check the
LEDs on the modules.
Note:
For information about how to check connectivity of modules, see the
Cisco NX-OS Fundamentals Configuration Guide.
Installing and Removing a Crossbar Fabric Module
This section includes the following topics:
v
“Installing and Removing a Crossbar Fabric Module”
v
“Installing a Crossbar Fabric Module”
v
“Removing a Crossbar Fabric Module” on page 80
Guideline for Installing a Cross Bar Fabric Module
Note:
We recommend that you follow this guideline while installing the cross bar
fabric module.
Depending on the number of the crossbar fabric modules in the chassis
configuration, the following slot number should be assigned on the IBM c-type
SAN Device :
Number of Crossbar Fabric Modules
Slots Number
2
1 and 2
3
1, 3, and 5
4
1, 2, 3, and 5
5
1, 2, 3, 4, and 5
6
1, 2, 3, 4, 5, and 6
Installing a Crossbar Fabric Module
About this task
To install a crossbar module in the IBM c-type SAN Device, follow these steps:
Procedure
1.
Before installing any modules, install at least one Supervisor-1 module.
2.
Remove the fan module that is over the crossbar fabric module to be removed.
For more information on how to remove a fan module, see “Removing a
Crossbar Fabric Module” on page 80
Chapter 3. Installing the IBM c-type SAN Device
79
Summary of Contents for SAN192C-6
Page 2: ......
Page 8: ...vi SAN192C 6 SAN384C 6 and SAN768C 6 Installation Service and User Guide ...
Page 10: ...viii SAN192C 6 SAN384C 6 and SAN768C 6 Installation Service and User Guide ...
Page 24: ...xxii SAN192C 6 SAN384C 6 and SAN768C 6 Installation Service and User Guide ...
Page 114: ...90 SAN192C 6 SAN384C 6 and SAN768C 6 Installation Service and User Guide ...
Page 122: ...98 SAN192C 6 SAN384C 6 and SAN768C 6 Installation Service and User Guide ...
Page 143: ...Figure 47 AJK2 Figure 48 AJK1 Figure 49 AJJY Appendix B Cable and Port Specifications 119 ...
Page 144: ...Figure 50 AJJV 120 SAN192C 6 SAN384C 6 and SAN768C 6 Installation Service and User Guide ...
Page 146: ...122 SAN192C 6 SAN384C 6 and SAN768C 6 Installation Service and User Guide ...
Page 158: ...134 SAN192C 6 SAN384C 6 and SAN768C 6 Installation Service and User Guide ...
Page 159: ......
Page 160: ...IBM Part Number 02JD693 Printed in USA SC27 9276 00 1P P N 02JD693 ...