DANGER
You have already switched on the 2145 UPS-1U. The output sockets of the
2145 UPS-1U are live.
3.
Plug the signal cable into the serial connector
3
located on the SAN Volume
Controller 2145-CF8 node.
4.
Place the other end of the signal cable into the communication port
6
on the
2145 UPS-1U.
The SAN Volume Controller 2145-CF8 power is now connected to the 2145
UPS-1U.
Installing the SAN Volume Controller 2145-CF8 cable-retention
brackets
Two power cords run from the uninterruptible power-supply to each of the two
SAN Volume Controller 2145-CF8 power supplies. To anchor the power cords,
install the two cable-retention brackets on the back of the SAN Volume Controller
2145-CF8.
The cable-retention brackets install without tools, as shown in Figure 33.
To attach the brackets, perform the following steps:
1.
Loosely install the cable-retention bracket on a power cord by slipping the
power cord into the notch on the rear of the bracket.
2.
Align the cable-retention bracket on the power cord so that the bracket is to the
left side of the cord, as shown by
2
in Figure 33.
3.
Push both the bracket and the cable toward the SAN Volume Controller
2145-CF8 power supply (
2
), carefully aligning the power cord with the power
connector on the power supply and the bracket with the power-supply handle.
4.
Carefully push the bracket against the power-supply handle to force the spring
clip (
1
) over the leading edge of the handle.
5.
Push the cable and the bracket into place, as shown in Figure 33.
1
2
Figure 33. SAN Volume Controller 2145-CF8 cable-retention brackets
Chapter 2. Installing the SAN Volume Controller 2145-CF8 hardware
33
Summary of Contents for SAN Volume Controller 2145-CF8
Page 2: ......
Page 8: ...vi IBM System Storage SAN Volume Controller Model 2145 CF8 Hardware Installation Guide...
Page 10: ...viii IBM System Storage SAN Volume Controller Model 2145 CF8 Hardware Installation Guide...
Page 16: ...xiv IBM System Storage SAN Volume Controller Model 2145 CF8 Hardware Installation Guide...
Page 26: ...xxiv IBM System Storage SAN Volume Controller Model 2145 CF8 Hardware Installation Guide...
Page 32: ...6 IBM System Storage SAN Volume Controller Model 2145 CF8 Hardware Installation Guide...
Page 64: ...38 IBM System Storage SAN Volume Controller Model 2145 CF8 Hardware Installation Guide...
Page 66: ...40 IBM System Storage SAN Volume Controller Model 2145 CF8 Hardware Installation Guide...
Page 92: ...66 IBM System Storage SAN Volume Controller Model 2145 CF8 Hardware Installation Guide...
Page 99: ......
Page 100: ...Part Number 31P1135 Printed in USA GC52 1356 01 1P P N 31P1135...