Note: If the Capacity Upgrade on Demand processor feature is not installed, the
service representative should install the processor feature at this time. Do
not
continue with the steps below. Refer to the installation instructions that were
provided with the feature.
To install a system with the Capacity Upgrade on Demand feature hardware, do the
following:
1. Log in to the system as root user or as a user with system group privileges.
2. Type the following command:
chcod
Record the displayed information below:
Current MailAddress _______Reserved________
Current CustInfo
_______________________
Current Model and System ID = IBM, xxxx-______IBM, ________
Current number of authorized proc(s) out of (xx_____) installed on system = (yy_____)
where (xx) is the number of processors installed in the system, (yy) is the number of
Capacity Upgrade on Demand-enabled processors.
If (yy) is equal to 0, then Capacity Upgrade on Demand is not enabled.
If (yy) is greater than 0, then Capacity Upgrade on Demand is enabled.
3. To enable testing of all the installed processors, disable Capacity Upgrade on
Demand by setting the number _of _ processors (yy) equal to 0:
chcod -r proc -n 0
4. Shut down and reboot the system, as follows:
shutdown -Fr
5. To verify the installed processors, type the following at the command line:
bindprocessor -q
Information about installed processor boards displays. The available processors
should be listed as 0 to 7.
If the number of installed processors is not correct, use the normal maintenance
package procedures to correct any problems.
6. To test the system, type the following at the command line:
diag
7. Select Advanced Diagnostics.
8. Select System Verification mode on sysplanar0 and all processors. Use the normal
maintenance package procedures to correct any problems.
44
Installation Guide
Summary of Contents for RS/6000 Enterprise Server M80
Page 6: ...vi Installation Guide...
Page 10: ...x Installation Guide...
Page 12: ...xii Installation Guide...
Page 54: ...40 Installation Guide...
Page 66: ...52 Installation Guide...
Page 70: ...56 Installation Guide...
Page 72: ...58 Installation Guide...
Page 74: ...60 Installation Guide...
Page 82: ...68 Installation Guide...
Page 93: ......
Page 94: ...IBMR Part Number 09P4388 Printed in U S A September 2001 SA38 0576 02 1P P N 09P4388...