6. Press F3 and select
System Remote Alerts
.
System alerts
System alerts are generated for events that occur as a result of system
errors.
Table 20. System remote alerts
Alphanumeric
pager code
Event
Action
20
POST timeout
Generates an alert if an enabled POST timeout value is exceeded. The
POST timeout value is configured in the Server Timeouts section in the
System window.
21
O/S timeout
Generates an alert if an enabled operating system timeout value is
exceeded. The operating system timeout value is configured in the
Server Timeouts section in the System window. This
O/S timeout
field
must be set to
Enabled
for remote blue screen capture.
22
Test alert
Generates an alert if
Generate Test Alert
is clicked on the Remote Alert
Recipients page.
23
Power off
Generates an alert if the server is turned off.
24
Power on
Generates an alert if the server is turned on.
25
Boot failure
Generates an alert if an error occurs that prevents the server from
starting.
26
Loader timeout
Generates an alert if an enabled system loader timeout value is
exceeded. The system loader timeout value is configured in the Server
Timeouts section in the System window.
27
PFA notification
Generates an alert if a PFA notification is generated by the server
hardware. This feature is available only on servers that have
PFA-enabled hardware.
28 - 29
Reserved for future use.
7. Press F3 and select
Events For Local Notification
.
8. Select the events that you want to store in the event log. The Remote
Supervisor Adapter stores the notification only in the event log.
Local events
Local events are generated for events sent to IBM Director, if it is
installed, on the server where the ASM subsystem resides. These
events are not sent to remote alert recipients.
Table 21. Local events
Event
Action
Temperature
Generates a local notification if any of the monitored temperatures exceeds their
thresholds.
Voltage
Generates a local notification if any of the monitored voltages exceeds their threshold.
Redundant power supply
Generates a local notification if the redundant power supply fails.
Power off
Generates a local notification if the server is turned off.
Remote login
Generates a local notification if a remote login occurs.
System tamper
Generates a local notification if the server covers are removed. This feature is not
available on all servers.
Event log 75% full
Generates a local notification if the event log reaches 75% of capacity.
Event log full
Generates a local notification if the event log is full. When the event log is full, the
oldest events are deleted.
Chapter 7. Configuring your Remote Supervisor Adapter using a text-based interface
83
Summary of Contents for Remote Supervisor Adapter
Page 1: ...Remote Supervisor Adapter User s Guide...
Page 2: ......
Page 3: ...Remote Supervisor Adapter User s Guide...
Page 18: ...12 Remote Supervisor Adapter User s Guide...
Page 60: ...54 Remote Supervisor Adapter User s Guide...
Page 70: ...64 Remote Supervisor Adapter User s Guide...
Page 102: ...96 Remote Supervisor Adapter User s Guide...
Page 118: ...112 Remote Supervisor Adapter User s Guide...
Page 122: ...116 Remote Supervisor Adapter User s Guide...
Page 123: ......
Page 124: ...Part Number 48P9833 Printed in U S A 1P P N 48P9833...