If you are logged in to the ASM processor, a window similar to the one in the
following illustration opens.
Note:
Only Serial Port 1 appears on the Serial Port page when you are
logged in to the Remote Supervisor Adapter.
4. In the
Baud rate
field, select the data-transfer rate.
Use the
Baud rate
field to specify the data-transfer rate of your serial port
connection. To set the baud rate, select the data-transfer rate, in bits per
second, that corresponds to your serial port connection.
5. In the
Parity
field, select the error detection to be used in your serial
connection.
6. Select the number of data-terminating 1-bits in the
Stop bits
field that will
follow the data or any parity bit to mark the end of a transmission (normally a
byte or character).
Note:
The number of data bits is preset to 8 and cannot be changed.
7. If you are logged in to a Remote Supervisor Adapter installed in a non-xSeries
330 server: Select the
Dedicate to ASM
check box to reserve the serial port
for the Remote Supervisor Adapter.
When shared with the operating system, the serial port serves the Remote
Supervisor Adapter only while the server is turned off or during the power-on
self-test (POST). The operating system can access it after the POST is
completed. The Remote Supervisor Adapter takes over the serial port from the
operating system to dial out and transmit an alert only after a critical event.
The port then remains under Remote Supervisor Adapter control until the
server is restarted.
Note:
If you have configured a PPP interface, you must dedicate the serial
port to the Remote Supervisor Adapter, or you will lose the PPP port
when the host restarts.
Chapter 3. Configuring your Remote Supervisor Adapter or ASM processor
31
Summary of Contents for Remote Supervisor Adapter
Page 1: ...Remote Supervisor Adapter User s Guide...
Page 2: ......
Page 3: ...Remote Supervisor Adapter User s Guide...
Page 18: ...12 Remote Supervisor Adapter User s Guide...
Page 60: ...54 Remote Supervisor Adapter User s Guide...
Page 70: ...64 Remote Supervisor Adapter User s Guide...
Page 102: ...96 Remote Supervisor Adapter User s Guide...
Page 118: ...112 Remote Supervisor Adapter User s Guide...
Page 122: ...116 Remote Supervisor Adapter User s Guide...
Page 123: ......
Page 124: ...Part Number 48P9833 Printed in U S A 1P P N 48P9833...