Critical alerts
Critical alerts are generated for events that signal that the server is no
longer functioning.
Table 18. Critical remote alerts
Alphanumeric
pager code
Event
Action
00
Temperature irregularity Generates an alert if any of the monitored temperatures are outside
critical threshold values. Select
Temperature Tables
in the Temperature,
Voltage and Fan window to view the threshold values. If a critical
temperature condition is detected, the server automatically shuts down
and turns off.
01
Voltage irregularity
Generates an alert if the voltages of any of the monitored power supplies
fall outside their specified operational ranges. Select
Voltage Tables
in
the Temperature, Voltage and Fan window to view the threshold values.
If a critical voltage condition is detected, the server automatically shuts
down and turns off.
02
Tampering
Generates an alert if physical intrusion of the server box is detected.
Tamper monitoring is not available on some servers, in which case this
setting is ignored.
03
Multiple fan failure
Generates an alert if two or more of the cooling fans in the server fail.
04
Power failure
Generates an alert if any of the server power supplies fail.
05
Hard disk drive failure
Generates an alert if one or more of the hard disk drives in the server
fail.
06
VRM failure
Generates an alert if one or more voltage regulator modules (VRMs) fail.
VRMs are not used on some servers, in which case this setting is
ignored.
07-09
Reserved for future use.
Warning alerts
Warning alerts are generated for events that might progress to a
critical/error level.
Table 19. Warning remote alerts
Alphanumeric
pager code
Event
Action
10
Redundant power
supply failure
Generates an alert if a redundant power supply fails.
11
Single fan failure
Generates an alert if one fan fails.
12
Temperature irregularity Generates an alert if any monitored temperatures are outside the
warning threshold values. Select
Temperature Tables
in the
Temperature, Voltage and Fan window to view the threshold values.
Unlike the critical temperature event, this event will not initiate system
shutdown.
13
Voltage irregularity
Generates an alert if any monitored voltages are outside the warning
threshold values. Select
Voltage Tables
in the Temperature, Voltage and
Fan window to view the threshold values. Unlike the critical voltage
event, this event will not initiate an automatic system shutdown.
14 - 19
Reserved for future use.
Note:
Hard disk drive Predictive Failure Analysis (PFA) alerts are not
monitored.
82
Remote Supervisor Adapter: User’s Guide
Summary of Contents for Remote Supervisor Adapter
Page 1: ...Remote Supervisor Adapter User s Guide...
Page 2: ......
Page 3: ...Remote Supervisor Adapter User s Guide...
Page 18: ...12 Remote Supervisor Adapter User s Guide...
Page 60: ...54 Remote Supervisor Adapter User s Guide...
Page 70: ...64 Remote Supervisor Adapter User s Guide...
Page 102: ...96 Remote Supervisor Adapter User s Guide...
Page 118: ...112 Remote Supervisor Adapter User s Guide...
Page 122: ...116 Remote Supervisor Adapter User s Guide...
Page 123: ......
Page 124: ...Part Number 48P9833 Printed in U S A 1P P N 48P9833...