Summary of the ServeRAID-MR10M SAS/SATA Controller Characteristics 1-15
Step 1. Make sure that you clear the configuration on the system to
which you migrate the drives, to prevent a configuration data
mismatch between the drives and the NVRAM.
Note:
When you migrate drives, move only the disks that make
up the virtual disk (not all of the physical disks in an array),
so that you do not have an NVRAM mismatch error
(providing a configuration is on the destination controller).
The NVRAM mismatch error appears only if you move all
of the drives to the other controller.
Step 2. Turn off the power to the server and all physical disks,
enclosures, and system components. Disconnect the power
cords from the systems.
Step 3. Open the host system by following the instructions in the host
system technical documentation.
Step 4. Remove the SAS cable connectors from the external drives that
you want to migrate.
a. Make sure that pin 1 on the cable matches pin 1 on the
connector.
b. Make sure that the SAS cables conform to all SAS
specifications.
Step 5. Remove the physical disks from the first system, and insert
them into drive bays on the second system.
Step 6. Connect the SAS cables to the physical disks in the second
system.
Step 7. Determine the SAS target requirements.
Step 8. Perform a safety check.
a. Make sure that all of the cables are attached correctly.
b. Make sure that the RAID controller is installed correctly.
c. Close the cabinet of the host system.
Step 9. Reconnect the power cords to the system.
Step 10. Turn on the power to the system.
The controller detects the RAID configuration from the configuration data
on the drives.
Summary of Contents for Redbooks ServeRAID-MR10M
Page 1: ...IBM P N 81Y1995 ServeRAID MR10M USER S GUIDE J u n e 2 0 1 0...
Page 12: ...xii Contents...
Page 14: ...xiv Contents...
Page 16: ...xvi Contents...
Page 34: ...1 18 Overview...
Page 58: ...5 6 Installing the Intelligent Battery Backup Unit...
Page 74: ...6 16 Using the Intelligent Battery Backup Unit...
Page 80: ...A 4 Notices...
Page 86: ...B 6 Glossary of Terms and Abbreviations...
Page 87: ......
Page 88: ...81Y1995...