Placing the rack-mounted system into the operating position
Use this procedure to place the rack-mounted system into the operating position.
When you place the system in the operating position, ensure that the cables at the rear of the system do
not catch or bind as you push the system unit back into the rack.
To place a rack-mounted system in the operating position, complete the following steps:
1.
Ensure that you have the electrostatic discharge (ESD) wrist strap attached. If not, attach it now.
2.
Unlock the blue rail safety latches (A) by lifting them upward.
3.
Push the system unit (B) back into the rack until both system unit release latches lock into position.
4.
Secure the server to the rack by using shipping screws.
5.
If you have not already done so, replace the front cover. For instructions, see “Installing the front
cover” on page 134.
Air baffle
Use this procedure to open, close, remove, and replace the air baffle in an 8247-42L, 8286-41A, or
8286-42A system.
Opening the air baffle on an 8247-42L, 8286-41A, or 8286-42A system
Use this procedure to open the air baffle on an 8247-42L, 8286-41A, or 8286-42A system.
To open the air baffle, complete the following steps:
1.
Ensure that you have the electrostatic discharge (ESD) wrist strap attached. If not, attach it now.
2.
Pull the latches (A) to disengage the air baffle from the chassis.
P8HAJ654-1
A
B
Figure 135. Placing the system into the operating position
150
System backplane
Summary of Contents for Power Systems 8247-42L
Page 1: ...Power Systems System backplane for the 8247 42L 8286 41A or 8286 42A IBM...
Page 2: ......
Page 3: ...Power Systems System backplane for the 8247 42L 8286 41A or 8286 42A IBM...
Page 8: ...vi System backplane...
Page 18: ...xvi System backplane...
Page 23: ...1 2 or 1 2 or 1 2 3 4 or 1 2 3 4 or System backplane 5...
Page 80: ...1 2 or 1 2 or 1 2 3 4 or 1 2 3 4 or 62 System backplane...
Page 214: ...196 System backplane...
Page 226: ...208 System backplane...
Page 227: ......
Page 228: ...IBM...