Diagnostic error codes
Refer to the following Diagnostic Error Codes when using
the IBM PC Enhanced Diagnostics test.
In the following index, “X” can represent any number.
Diagnostic Error Code
FRU/Action
000-000-XXX
BIOS Test Passed
1. No action
000-002-XXX
BIOS Timeout
1. Flash the system
2. System board
000-024-XXX
BIOS Addressing test failure
1. Flash the system
2. System board
000-025-XXX
BIOS Checksum Value error
1. Flash the system
2. Boot block
3. System board
000-026-XXX
FLASH data error
1. Flash the system
2. Boot block
3. System board
000-027-XXX
BIOS Configuration/Setup
error
1. Run Setup
2. Flash the system
3. Boot block
4. System board
000-034-XXX
BIOS Buffer Allocation
failure
1. Reboot the system
2. Flash the system
3. Run memory test
4. System board
000-035-XXX
BIOS Reset Condition
detected
1. Flash the system
2. System board
000-036-XXX
BIOS Register error
1. Flash the system
2. Boot block
3. System board
000-038-XXX
BIOS Extension failure
1. Flash the system
2. Adapter card
3. System board
000-039-XXX
BIOS DMI data error
1. Flash the system
2. System board
000-195-XXX
BIOS Test aborted by user
1. Information
2. Re-start the test, if
need to
000-196-XXX
BIOS test halt, error
threshold exceeded
1. Press F3 to review
the log file. See
“Viewing the test
log” on page 14.
2. Re-start the test to
reset the log file.
IBM Netfinity 1000 - Type 8477
169
Summary of Contents for Netfinity 1000-8477 21Y
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 236: ...228 Netfinity Server HMM...
Page 237: ...Related service information 229...
Page 238: ...230 Netfinity Server HMM...
Page 239: ...Related service information 231...
Page 240: ...232 Netfinity Server HMM...
Page 253: ...Related service information 245...
Page 254: ...246 Netfinity Server HMM...
Page 255: ...Related service information 247...
Page 267: ......
Page 268: ...IBM Part Number 09N1594 Printed in U S A S N 4129 1...