Error code
Description
Action
215-803-xxx
Failed the optical drive self test due to the
disk possibly being in use by the system.
1.
Wait for the system activity to stop; then, rerun
the test. See .
2.
Turn off and turn on the system, then; rerun the
test. See “Turning off the blade server” on page
13, “Turning on the blade server” on page 13
and “Diagnostic tools overview” on page 97.
3.
If the component failure remains, see your
BladeCenter documentation for information
about replacing the optical drive (media tray).
4.
If the failure remains, collect the data from the
DSA event log (“Diagnostic tools overview” on
page 97) and send it to IBM Service. For
information about contacting and sending data
to IBM Service, see “Hardware service and
support” on page 227.
215-901-xxx
Aborted the optical drive self test because the
drive media was not detected.
1.
Insert a new CD or DVD into the drive and
wait for 15 seconds for the media to be
recognized; then, rerun the test. See“Diagnostic
tools overview” on page 97.
2.
Make sure that the cable for the optical drive is
securely connected at both ends of the cable and
tighten any loose connections. See your
BladeCenter documentation for information
about the optical drive (media tray).
3.
Make sure that the cable for the optical drive is
not damaged and replace the cable if damage is
present. See your BladeCenter documentation
for information about the optical drive (media
tray).
4.
Rerun the test. See “Diagnostic tools overview”
on page 97.
5.
For additional troubleshooting information, go
to http://www.ibm.com/support/
docview.wss?uid=psg1MIGR-41559.
6.
Rerun the test. See“Diagnostic tools overview”
on page 97.
7.
Replace the CD or DVD drive. See your
BladeCenter documentation for information
about replacing the optical drive (media tray).
8.
If the failure remains, collect the data from the
DSA event log (“Diagnostic tools overview” on
page 97) and send it to IBM Service. For
information about contacting and sending data
to IBM Service, see “Hardware service and
support” on page 227.
208
BladeCenter HS22V Type 7871 and 1949: Problem Determination and Service Guide
Summary of Contents for BladeCenter HS22V 7871
Page 1: ...BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Page 16: ...xiv BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Page 20: ...4 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Page 34: ...18 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Page 64: ...48 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Page 112: ...96 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Page 240: ...224 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...