v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 4, “Parts listing, Types 7871 and 1949,” on page 41 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
Trained service technician.
Error code
Description
Action
3048006
Booted secondary (backup) UEFI image due
to ABR.
1.
Run the Setup utility (see “Using the Setup
utility” on page 20). Select
Load Default Settings
and save the settings.
2.
Follow the UEFI recovery procedure in
“Recovering from a UEFI update failure” on page
212.
3138002
Boot configuration error.
1.
Run the Setup utility and remove any recent
changes made to the settings (see “Using the
Setup utility” on page 20).
2.
Run the Setup utility (see “Using the Setup
utility” on page 20). Select
Load Default Settings
and save the settings.
3008000
IMM communication failure.
1.
Reseat the blade server (see “Removing the blade
server from the BladeCenter unit” on page 52
and “Installing the blade server in a BladeCenter
unit” on page 53).
2.
Update the IMM firmware (see “Firmware
updates” on page 33).
3.
(Trained service technician only) If the problem
remains, replace the system board (see
“Removing the system-board assembly” on page
94 and “Installing the system-board assembly” on
page 95).
3008001
IMM incompatible firmware level.
1.
Reseat the blade server (see “Removing the blade
server from the BladeCenter unit” on page 52
and “Installing the blade server in a BladeCenter
unit” on page 53).
2.
Update the IMM firmware (see “Firmware
updates” on page 33).
3.
(Trained service technician only) If the problem
remains, replace the system board (see
“Removing the system-board assembly” on page
94 and “Installing the system-board assembly” on
page 95).
3008002
Configuration update to IMM failed.
1.
Reseat the blade server (see “Removing the blade
server from the BladeCenter unit” on page 52
and “Installing the blade server in a BladeCenter
unit” on page 53).
2.
Update the IMM firmware (see “Firmware
updates” on page 33).
3.
(Trained service technician only) If the problem
remains, replace the system board (see
“Removing the system-board assembly” on page
94 and “Installing the system-board assembly” on
page 95).
Chapter 6. Diagnostics
161
Summary of Contents for BladeCenter HS22V 1949
Page 1: ...BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Page 16: ...xiv BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Page 20: ...4 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Page 34: ...18 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Page 64: ...48 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Page 112: ...96 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Page 240: ...224 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Page 244: ...228 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Page 252: ...236 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Page 257: ......
Page 258: ...Part Number 00Y8038 Printed in USA 1P P N 00Y8038...