008 - DOES THE DIAGNOSTICS FINISH WITHOUT ANY ERRORS? (YES,
READ AHEAD. NO, GO TO STEP 009.)
q
If the
Diagnostics \ All Tests
did not detect a failure but the system still
indicates a failure:
q
Check all adapter card jumper settings.
q
Check all adapter card switch settings.
q
Check all adapter card cables and connectors.
q
Make sure that all of the above are set correctly and show the correct
voltages and continuity. Replace any defective cables or adapter cards.
See “Power Supply Cable Connector Specifications” on page 5-7 and
“Aptiva Type 2187 System Board Layout” on page 5-3.
q
Run the Diagnostics \ All Tests again.
q
If an error or other symptom is displayed, go to “Index of Symptoms,
Messages, Error Codes, or Beeps” on page 2-8.
q
If no error can be detected or the symptom is intermittent, go to
"Undetermined Problems” on page 2-40.
q
End
009 -
q
If the last test stops and you cannot continue, first make sure all switches,
power connectors, cables, and jumpers are set correctly and show the
correct voltages and continuity.
q
Take note of any messages, error codes, beeps, or new symptoms. Go to
"Index of Symptoms, Messages, Error Codes, or Beeps" on page 2-8.
q
If there is no error symptom or the error symptom is intermittent, go to
“Undetermined Problems” on page 2-40.
Summary of Contents for Aptiva 2187
Page 1: ...Hardware Maintenance Service for Service Level A Aptiva Type 2187 2187...
Page 15: ...XIII...
Page 16: ...XIV...
Page 17: ...XV...
Page 18: ...XVI...
Page 19: ...XVII...
Page 30: ...XXVIII...
Page 31: ...XXIX...
Page 32: ...XXX...
Page 104: ......
Page 110: ......
Page 119: ...4 9 q Pull the diskette drive from the mounting tray to remove it...
Page 144: ......
Page 148: ...7 2 Assembly 1 Aptiva Type 2187 System Unit...
Page 160: ......