1.
If the system supports slow boot (see Performing a slow boot), do
a slow boot on the system. If the system does not support slow
boot, do a normal boot.
2.
Power on the system.
3.
Wait until the AIX operating system login prompt displays or
until system activity on the operator panel or display apparently
has stopped.
Did the AIX Login Prompt display?
v
Yes:
Continue with the next step.
v
No:
Go to problem analysis.
8.
If the Resource Repair Action menu is already displayed, go to 12 on page 82; otherwise, do the
following steps:
1.
Log into the operating system, either with root authority (if
needed, ask the customer to enter the password) or use the CE
login.
2.
Enter the
diag -a
command and check for missing resources.
Follow any instructions that display. If an system request number
(SRN) displays, suspect a loose card or connection. If no
instructions display, no resources were detected as missing.
Continue with 9.
9.
Complete the following steps:
1.
Enter
diag
at the command prompt.
2.
Press Enter.
3.
Select the
Diagnostics Routines
option.
4.
When the Diagnostic Mode Selection menu displays, select
Problem determination
.
5.
When the Advanced Diagnostic Selection menu displays, select
the
All Resources
option, or test the FRUs you exchanged, and
any devices that are attached to the FRUs you exchanged, by
selecting the diagnostics for the individual FRU.
Did the Resource Repair Action menu (801015) display?
v
Yes:
Go to step 13 on page 82.
v
No:
Continue with the next step.
10.
Did the TESTING COMPLETE, no trouble was found menu (801010) display?
v
Yes:
Continue with the next step.
v
No:
There is still a problem. Go to problem analysis.
11.
Use the
Log Repair Action
option, if not previously logged, in the TASK SELECTION menu to
update the AIX error log. If the repair action was reseating a cable or adapter, select the resource
associated with that repair action.
Power supplies
81
Summary of Contents for 9117-MMB
Page 1: ...Power Systems Power supplies for the 9117 MMB 9117 MMC 9179 MHB or 9179 MHC ...
Page 2: ......
Page 3: ...Power Systems Power supplies for the 9117 MMB 9117 MMC 9179 MHB or 9179 MHC ...
Page 112: ...100 Power Systems Power supplies for the 9117 MMB 9117 MMC 9179 MHB or 9179 MHC ...
Page 113: ......
Page 114: ... Printed in USA ...