Did you encounter any problems?
No
Reinstall the operating system and continue with step 5.
Yes
If the original problem still exists, replace the
field-replaceable unit (FRU) or perform the isolation
procedure that is next in the FRU list. If you have reached
the end of the FRU list, contact your next level of support.
If a new problem has occurred, go to Beginning problem
analysis.
3.
Did you replace a FRU with the power turned on and concurrently with system operations?
No
Go to step 5.
Yes
Continue with the next step.
4.
Did you use an AIX diagnostics service aid hot-swap operation to change the FRU?
Yes
Go to step 6.
No
Go to step 7.
Note:
The AIX diagnostic service aid was
used if a resource was removed using the
Hot
Plug
task.
5.
Note:
If any FRUs have been removed that should be reinstalled, reinstall them now.
Perform the following steps:
1.
If the system is not powered on, power it on now.
2.
Perform a slow boot.
3.
Wait until the AIX operating system login prompt displays or until system activity on the operator panel or
display apparently has stopped.
4.
Did you encounter any problems?
No
Continue at step 6.
Yes
If the original problem still exists, replace the FRU or perform the isolation procedure that is next in the FRU
list. If you have reached the end of the FRU list, contact your next level of support.
If a new problem has occurred, go to Beginning problem analysis.
6.
If the Resource Repair Action menu is already displayed, go to step 9 on page 70; otherwise,
perform the following steps:
1.
Log into the operating system either with root authority (if
needed, ask the customer to enter the password) or use the CE
login.
2.
Enter the
diag -a
command and check for missing resources.
Follow any instructions that display. If an SRN displays, suspect a
loose card or connection. If no instructions display, no resources
were detected as missing. Continue with the next step.
7.
Perform the following steps:
Power supplies
69
Summary of Contents for 9117-MMB
Page 1: ...Power Systems Power supplies for the 9117 MMB 9117 MMC 9179 MHB or 9179 MHC ...
Page 2: ......
Page 3: ...Power Systems Power supplies for the 9117 MMB 9117 MMC 9179 MHB or 9179 MHC ...
Page 112: ...100 Power Systems Power supplies for the 9117 MMB 9117 MMC 9179 MHB or 9179 MHC ...
Page 113: ......
Page 114: ... Printed in USA ...