Temperature
error
messages
Note:
See
“System
replaceable
units”
on
page
131
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Message
Action
DASD
Over
Temperature
(level-critical;
direct
access
storage
device
bay
x
was
over
temperature)
v
Ensure
that
the
system
is
being
properly
cooled;
see
“System
reliability
guidelines”
on
page
25.
DASD
Over
recommended
Temperature
(sensor
x
)
(level-warning;
DASD
bay
x
had
over
temperature
condition)
v
Ensure
that
the
system
is
being
properly
cooled;
see
“System
reliability
guidelines”
on
page
25.
DASD
under
recommended
temperature
(sensor
x
)
(level-warning;
direct
access
storage
device
bay
x
had
under
temperature
condition)
v
Ambient
temperature
must
be
within
normal
operating
specifications;
see
“Features
and
specifications”
on
page
3.
DASD
Over
Temperature
(level-critical;
sensor
for
DASD1
reported
temperature
over
recommended
range)
v
Ensure
that
the
system
is
being
properly
cooled;
see
“System
reliability
guidelines”
on
page
25.
Power
supply
x
Temperature
Fault
(level-critical;
power
supply
x
had
over
temperature
condition)
1.
Ensure
system
is
being
properly
cooled;
see
“System
reliability
guidelines”
on
page
25.
2.
Power
supply
x
.
System
board
is
over
recommended
temperature
(level-warning;
system
board
is
over
recommended
temperature)
1.
Ensure
system
is
being
properly
cooled
;
see
“System
reliability
guidelines”
on
page
25.
2.
System
board.
System
board
is
under
recommended
temperature
(level-warning;
system
board
is
under
recommended
temperature)
v
Ambient
temperature
must
be
within
normal
operating
specifications;
see
“Features
and
specifications”
on
page
3.
System
over
temperature
for
CPU
x
(level-warning;
CPU
x
reporting
over
temperature
condition)
v
Ensure
system
is
being
properly
cooled;
see
“System
reliability
guidelines”
on
page
25.
System
under
recommended
CPU
x
temperature
(level-warning;
system
reporting
under
temperature
condition
for
CPU
x)
v
Ambient
temperature
must
be
within
normal
operating
specifications
;
see
“Features
and
specifications”
on
page
3.
Fan
error
messages
Note:
See
“System
replaceable
units”
on
page
131
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Message
Action
Fan
x
failure
(level-critical;
fan
x
had
a
failure)
1.
Check
connections
to
fan
x
.
2.
Replace
fan
x
.
Fan
x
fault
(level-critical;
fan
x
beyond
recommended
RPM
range)
1.
Check
connections
to
fan
x
.
2.
Replace
fan
x
.
Fan
x
outside
recommended
speed
action
v
Replace
fan
x
.
Chapter
6.
Symptom-to-FRU
index
123
Summary of Contents for 84885BU
Page 1: ...xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 2: ......
Page 3: ...xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 34: ...24 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 106: ...96 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 163: ...Appendix B Safety information 153 ...
Page 164: ...154 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 165: ...Appendix B Safety information 155 ...
Page 166: ...156 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 167: ...Appendix B Safety information 157 ...
Page 168: ...158 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 169: ...Appendix B Safety information 159 ...
Page 179: ...Appendix B Safety information 169 ...
Page 180: ...170 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 181: ...Appendix B Safety information 171 ...
Page 182: ...172 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 186: ...176 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 198: ...188 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 199: ......
Page 200: ... Part Number 25K8108 Printed in USA 1P P N 25K8108 ...