Error
code/symptom
FRU/action
166-342-000
System
Management:
Failed
(RSA
BIST
indicate
failed
tests.)
1.
Make
sure
that
the
latest
firmware
levels
for
Remote
Supervisor
Adapter
II
and
BIOS
are
installed.
2.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect,
and
retry.
3.
Remote
Supervisor
Adapter
II.
180-XXX-000
(Diagnostics
LED
failure)
v
Run
diagnostic
LED
test
for
the
failing
LED.
180-XXX-001
(Failed
Front
LED
panel
test)
v
Information
LED
panel
180-XXX-002
(Failed
Diagnostics
LED
panel
test)
v
System
board
180-XXX-003
(Failed
system
board
LED
test)
v
System
board
180-XXX-005
(Failed
SCSI
Backplane
LED
test)
1.
SCSI
backplane
2.
SCSI
backplane
cable
3.
System
board
201-XXX-0NN
(Failed
Memory
test,
see
“Installing
a
memory
module”
on
page
34)
1.
DIMM
Location
slots
1-6
where
NN
=
DIMM
location.
Note:
NN
1=DIMM
1
NN
2=DIMM
2
NN
3=DIMM
3
NN
4=DIMM
4
NN
5=DIMM
5
NN
6=DIMM
6
2.
System
board
202-XXX-001
(Failed
System
Cache
test)
1.
Microprocessor
1
2.
System
board
202-XXX-002
(Failed
System
Cache
test)
1.
Microprocessor
2
2.
System
board
206-XXX-000
(Failed
Diskette
Drive
test)
1.
Rerun
the
test
with
another
diskette.
2.
Diskette
drive
cables.
3.
Diskette
drive.
4.
System
board.
214-XXX-000
(Failed
Diskette
Drive
test)
1.
Rerun
the
test
with
another
diskette.
2.
Cable.
3.
Diskette
drive.
4.
System
board.
215-XXX-000
(Failed
IDE
CD-ROM
test)
1.
Rerun
the
test
with
a
different
CD.
2.
CD-ROM
drive
cables.
3.
CD-ROM
drive.
4.
System
board.
217-198-XXX
(Could
not
establish
drive
parameters)
1.
Check
the
cable
and
termination.
2.
SCSI
backplane.
3.
Hard
disk
drive.
.
217-XXX-000
(Failed
Fixed
Disk
test)
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
1.
Fixed
Disk
1
2.
System
board
217-XXX-001
(Failed
BIOS
Fixed
Disk
test)
Note:
If
RAID
is
configured,
the
fixed
disk
number
refers
to
the
RAID
logical
array.
1.
Fixed
Disk
2
2.
System
board
Chapter
6.
Symptom-to-FRU
index
107
Summary of Contents for 84885BU
Page 1: ...xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 2: ......
Page 3: ...xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 34: ...24 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 106: ...96 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 163: ...Appendix B Safety information 153 ...
Page 164: ...154 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 165: ...Appendix B Safety information 155 ...
Page 166: ...156 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 167: ...Appendix B Safety information 157 ...
Page 168: ...158 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 169: ...Appendix B Safety information 159 ...
Page 179: ...Appendix B Safety information 169 ...
Page 180: ...170 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 181: ...Appendix B Safety information 171 ...
Page 182: ...172 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 186: ...176 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 198: ...188 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 199: ......
Page 200: ... Part Number 25K8108 Printed in USA 1P P N 25K8108 ...