ServeRAID
error
codes
In
the
following
error
codes,
x
can
be
any
number
or
letter.
Note:
See
“System
replaceable
units”
on
page
131
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Error
code/symptom
FRU/action
1xxx
(Microcode
checksum
error)
1.
ServeRAID
controller
2xxx
(Code
DRAM
error)
1.
Install
download
jumpers,
flash
latest
level
BIOS
and
firmware
for
controller.
Remove
jumpers.
2.
ServeRAID
controller.
3000-31xx(Code
DRAM
error)
1.
Install
download
jumpers,
flash
latest
level
BIOS
and
firmware
for
controller.
Remove
jumpers.
2.
ServeRAID
controller.
3200
(Code
DRAM
error)
1.
Install
download
jumpers,
flash
latest
level
BIOS
code
and
firmware
for
controller.
Remove
jumpers.
2.
ServeRAID
controller.
3300
(ServeRAID-5i
only)
1.
Install
ServeRAID-5i
controller
in
an
extended
PCI
expansion
slot.
See
the
documentation
that
came
with
the
server
for
more
information.
3E20
(ServeRAID-5i
only)
1.
Remove
the
ServeRAID-5i
controller
from
its
slot
and
install
it
in
the
proper
PCI
option
slot.
2.
Verify
that
the
ServeRAID-5i
controller
is
supported
in
this
server.
3.
ServeRAID-5i
controller.
4.
System
board.
3E2x
1.
Reseat
the
ServeRAID
controller.
2.
Flash
latest
level
of
BIOS
code
and
firmware
for
controller.
3.
ServeRAID-5i
controller.
4.
Integrated
RAID
controller
on
serve).
4xxx
thru
5xxx
(Code
DRAM
error)
1.
Install
download
jumpers,
flash
latest
level
BIOS
code
and
firmware
for
controller;
then,
remove
jumpers.
2.
ServeRAID
controller.
6xxx
(Cache
DRAM
error)
(ServeRAID-4H
only)
1.
Reseat
daughter
card.
2.
Install
download
jumpers,
flash
latest
level
BIOS
code
and
firmware
for
controller;
then,
remove
jumpers.
3.
ServeRAID
controller.
7xxx
thru
8xxx
(Host/local
PCI
bus
interface
error)
1.
Flash
latest
level
of
BIOS
code
and
firmware
for
controller.
2.
If
ServeRAID-4x
controller,
replace
controller.
3.
If
ServeRAID-5i
controller,
integrated
RAID
controller
on
the
computer.
Chapter
6.
Symptom-to-FRU
index
119
Summary of Contents for 84885BU
Page 1: ...xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 2: ......
Page 3: ...xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 34: ...24 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 106: ...96 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 163: ...Appendix B Safety information 153 ...
Page 164: ...154 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 165: ...Appendix B Safety information 155 ...
Page 166: ...156 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 167: ...Appendix B Safety information 157 ...
Page 168: ...158 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 169: ...Appendix B Safety information 159 ...
Page 179: ...Appendix B Safety information 169 ...
Page 180: ...170 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 181: ...Appendix B Safety information 171 ...
Page 182: ...172 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 186: ...176 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 198: ...188 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 199: ......
Page 200: ... Part Number 25K8108 Printed in USA 1P P N 25K8108 ...