![IBM 84885BU Maintenance And Troubleshooting Manual Download Page 115](http://html1.mh-extra.com/html/ibm/84885bu/84885bu_maintenance-and-troubleshooting-manual_4115661115.webp)
Error
code/symptom
FRU/action
001-250-000
(Failed
system
board
ECC)
v
System
board
001-250-001
(Failed
Processor
Board
ECC)
v
System
board
001-292-000
(Core
system:
failed/CMOS
checksum
failed)
v
Load
BIOS
code
defaults
and
rerun
test.
005-XXX-000
(Failed
Video
test)
1.
Video
adapter
2.
System
board
011-XXX-000
(Failed
COM1
Serial
Port
test)
1.
Check
loopback
plug
connected
to
externalized
serial
port.
2.
System
board.
011-XXX-001
(Failed
COM2
Serial
Port
test)
1.
Check
loopback
plug
connected
to
externalized
serial
port.
2.
Check
cable
from
externalized
port
to
system
board.
Should
connect
to
serial
port
B
on
the
system
board
(JCOM1).
3.
System
board.
014-XXX-000
(Failed
Parallel
Port
test)
v
System
board
015-XXX-001
(USB
interface
not
found,
board
damaged)
v
System
board
015-XXX-198
(Remote
Supervisor
Adapter
II
installed)
or
(USB
device
connected
during
USB
test)
1.
If
Remote
Supervisor
Adapter
II
is
installed
as
an
option,
remove
it
and
rerun
test.
Note:
If
Remote
Supervisor
Adapter
II
is
present
as
a
standard
installation,
do
not
remove
it;
the
test
cannot
be
run.
2.
Remove
USB
devices
and
rerun
test.
3.
System
board
.
020-XXX-000
(Failed
PCI
Interface
test)
v
System
board
030-XXX-000
(Failed
Internal
SCSI
interface
test)
v
System
board
035-XXX-099
(No
adapters
were
found)
v
If
an
adapter
is
installed
re-check
the
connection.
035-XXX-S99
(Failed
RAID
test
on
PCI
slot
S,
check
System
Error
Log
before
replacing
a
FRU)
1.
RAID
adapter
2.
SCSI
backplane
3.
Cable
035-XXX-SNN
(Check
System
Error
Log
before
replacing
a
FRU,
NN
=
SCSI
ID
of
failing
fixed
disk)
v
Hard
disk
with
SCSI
ID
NN
on
RAID
adapter
in
PCI
slot
S.
035-253-S99
(RAID
adapter
initialization
failure)
1.
ServeRAID
Adapter
in
slot
S
is
not
configured
properly.
Obtain
the
basic
and
extended
configuration
status
and
see
the
ServeRAID
Hardware
Maintenance
Manual
for
more
information.
2.
Cable.
3.
SCSI
backplane.
4.
Adapter.
089-XXX-001
(Failed
Microprocessor
test)
1.
Microprocessor
1
2.
System
board
089-XXX-002
(Failed
Optional
Microprocessor
test)
1.
Microprocessor
2
2.
System
board
Chapter
6.
Symptom-to-FRU
index
105
Summary of Contents for 84885BU
Page 1: ...xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 2: ......
Page 3: ...xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 34: ...24 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 106: ...96 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 163: ...Appendix B Safety information 153 ...
Page 164: ...154 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 165: ...Appendix B Safety information 155 ...
Page 166: ...156 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 167: ...Appendix B Safety information 157 ...
Page 168: ...158 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 169: ...Appendix B Safety information 159 ...
Page 179: ...Appendix B Safety information 169 ...
Page 180: ...170 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 181: ...Appendix B Safety information 171 ...
Page 182: ...172 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 186: ...176 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 198: ...188 xSeries 226 Type 8488 and 8648 Hardware Maintenance Manual and Troubleshooting Guide ...
Page 199: ......
Page 200: ... Part Number 25K8108 Printed in USA 1P P N 25K8108 ...