Description
Action
I9990650
AC
power
has
been
restored.
1.
Reseat
the
power
cords.
2.
Check
for
interruption
of
the
external
power.
3.
Replace
the
power
cords.
ServerGuide
problems
The
following
table
lists
problem
symptoms
and
suggested
solutions.
Table
3.
ServerGuide
Setup
and
Installation
CD
Symptom
Action
The
ServerGuide
Setup
and
Installation
CD
will
not
start.
v
Make
sure
that
the
server
supports
the
ServerGuide
program
and
has
a
startable
(bootable)
CD
or
DVD
drive.
v
If
the
startup
(boot)
sequence
settings
have
been
changed,
make
sure
that
the
CD
or
DVD
drive
is
first
in
the
startup
sequence.
v
If
more
than
one
CD
or
DVD
drive
is
installed,
make
sure
that
only
one
drive
is
set
as
the
primary
drive.
Start
the
CD
from
the
primary
drive.
ServeRAID
program
cannot
view
all
installed
drives
or
the
operating
system
cannot
be
installed.
v
Make
sure
that
there
are
no
duplicate
IRQ
assignments.
v
Make
sure
that
the
hard
disk
drive
is
connected
correctly.
The
operating-system
installation
program
continuously
loops.
Make
more
space
available
on
the
hard
disk.
The
ServerGuide
program
will
not
start
the
operating-system
CD.
Make
sure
that
the
operating-system
CD
is
supported
by
the
ServerGuide
program.
See
the
ServerGuide
Setup
and
Installation
CD
label
for
a
list
of
supported
operating-system
versions.
The
operating
system
cannot
be
installed;
the
option
is
not
available.
Make
sure
that
the
operating-system
CD
is
supported
on
the
server.
If
the
operating
system
is
supported,
no
logical
drive
is
defined
(RAID
servers).
Run
the
ServerGuide
program
and
make
sure
that
setup
is
complete.
Troubleshooting
tables
Use
the
following
tables
to
find
solutions
to
problems
that
have
identifiable
symptoms.
See
the
Problem
Determination
and
Service
Guide
on
the
IBM
xSeries
Documentation
CD
for
more
detailed
troubleshooting
information.
If
you
cannot
find
the
problem
in
these
tables,
run
the
diagnostic
programs
(see
“Running
the
diagnostic
programs”
in
the
Problem
Determination
and
Service
Guide
).
If
you
have
just
added
new
software
or
a
new
optional
device
and
the
server
is
not
working,
complete
the
following
steps
before
using
the
troubleshooting
tables:
Chapter
5.
Solving
problems
63
Summary of Contents for 8485E2U
Page 3: ...xSeries 206m Types 8485 and 8490 Installation Guide...
Page 52: ...38 xSeries 206m Types 8485 and 8490 Installation Guide...
Page 62: ...48 xSeries 206m Types 8485 and 8490 Installation Guide...
Page 108: ...94 xSeries 206m Types 8485 and 8490 Installation Guide...
Page 109: ......
Page 110: ...Part Number 40K2367 Printed in USA 1P P N 40K2367...