8
IBM : Hardware Maintenance Manual
Physical specifications — small desktop model
Dimensions
Height: 104 mm (4.1 in.)
Width: 360 mm (14.2 in.)
Depth: 412 mm (16.2 in.)
Weight
Minimum configuration as shipped: 8.1 kg (18 lb)
Maximum configuration: 10.9 kg (24 lb)
Environment
Air temperature:
System on: 10
°
to 35
°
C (50
°
to 95
°
F)
System off: 10
°
to 43
°
C (50
°
to 110
°
F)
Maximum altitude: 2134 m (7000 ft)
Note:
The maximum altitude, 2134 m (7000 ft),
is the maximum altitude at which the
specified air temperatures apply. At
higher altitudes, the maximum air
temperatures are lower than those
specified.
Humidity:
System on: 8% to 80%
System off: 8% to 80%
Electrical input
Input voltage:
Low range:
Minimum: 90 V ac
Maximum: 137 V ac
Input frequency range: 57–63 Hz
Voltage switch setting: 115 V ac
High range:
Minimum: 180 V ac
Maximum: 265 V ac
Input frequency range: 47–53 Hz
Voltage switch setting: 230 V ac
Input kilovolt-amperes (kVA) (approximate):
Minimum configuration as shipped: 0.08 kVA
Maximum configuration: 0.30 kVA
Note:
Power consumption and heat output vary
depending on the number and type of
optional features installed and the power-
management optional features in use.
Heat output
(approximate) in British thermal units (Btu)
per hour:
Minimum configuration: 257 Btu/hr (75 watts)
Maximum configuration: 686 Btu/hr (200 watts)
Airflow
Approximately 0.45 cubic meters every three minutes
(16 cubic feet every three minutes) maximum
Acoustical noise-emission values
Average sound-pressure levels:
At operator position:
Idle: 38 dBA
Operating: 43 dBA
At bystander position - 1 meter (3.3 ft):
Idle: 33 dBA
Operating: 37 dBA
Declared (upper limit) sound-power levels:
Idle: 3.75 bels
Operating: 4.99 bels
Note:
These levels were measured in controlled
acoustical environments according to the
procedures specified by the American
National Standards Institute (ANSI) S12.10
and ISO 7779 and are reported in accordance
with ISO 9296. Actual sound-pressure levels
in a given location might exceed the average
values stated because of room reflections and
other nearby noise sources. The declared
sound-power levels indicate an upper limit,
below which a large number of computers
will operate.
Note:
The computer is classified as a Class A or
Class B digital device. See the
Quick Reference
for further information about this
classification.
Summary of Contents for 6343
Page 2: ......
Page 20: ...12 IBM Hardware Maintenance Manual...
Page 28: ...20 IBM Hardware Maintenance Manual...
Page 46: ...38 IBM Hardware Maintenance Manual...
Page 57: ...Chapter 4 Installing Options 49...
Page 116: ...108 IBM Hardware Maintenance Manual...
Page 182: ...174 IBM Hardware Maintenance Manual...
Page 192: ...184 IBM Hardware Maintenance Manual...
Page 203: ...Chapter 9 Related service information 195...
Page 204: ...196 IBM Hardware Maintenance Manual...
Page 205: ...Chapter 9 Related service information 197...
Page 206: ...198 IBM Hardware Maintenance Manual...
Page 207: ...Chapter 9 Related service information 199...
Page 208: ...200 IBM Hardware Maintenance Manual...
Page 209: ...Chapter 9 Related service information 201...
Page 210: ...202 IBM Hardware Maintenance Manual...
Page 220: ...212 IBM Hardware Maintenance Manual...
Page 221: ...Chapter 9 Related service information 213...
Page 222: ...214 IBM Hardware Maintenance Manual...
Page 229: ......
Page 230: ...IBM Part Number 24P2934 File Number 24P2934 0424P2934...