Table 10. Operating environmental conditions for the device (continued)
Description
Range
Operating noise
65 dB
Maximum heat dissipation
689 BTU/Hr
Storage environment
Table 11. Storage environmental conditions for the device
Description
Range
Storage temperature
-25° to 70°C (-23° to 158°F)
Storage humidity
80% maximum, non-condensing
Cooling
The B24X has three speed-adjustable fans that operate simultaneously. If one fan
fails, it does not affect the operation of the other fans. The cooling fans cool the
CPU, main memory, and voltage regulators. The fans use a pull configuration to
intake air from the front left and right sides through the device and then expel it at
the rear of the device as shown in Figure 27.
1
Left intake
3
Right intake
2
Front intakes
4
Exhaust
v
Total cooling capacity: 200 watts
v
Total air flow: 150 LFM
v
Fan operating noise: < 65 dB-A.
Note:
Operating noise is based on the ISO 7779 standard.
Power source interruptions
Table 12 shows how the B24X protects against power surges and power drops.
Table 12. Device power surge and drop protection
Property
Protection Mechanism
Power surge
MOV and Spark Gap protection
Power drop
The PSU will shut down after AC loss >20ms
WR
Mgm t
Consol e
1
2
3
4
netx018
Figure 27. Device air flow
44
IBM x-series of Ethernet Switches Installation and User Guide
Summary of Contents for 4002AC2
Page 2: ......
Page 8: ...vi IBM x series of Ethernet Switches Installation and User Guide...
Page 10: ...viii IBM x series of Ethernet Switches Installation and User Guide...
Page 12: ...x IBM x series of Ethernet Switches Installation and User Guide...
Page 34: ...8 IBM x series of Ethernet Switches Installation and User Guide...
Page 44: ...18 IBM x series of Ethernet Switches Installation and User Guide...
Page 56: ...30 IBM x series of Ethernet Switches Installation and User Guide...
Page 68: ...42 IBM x series of Ethernet Switches Installation and User Guide...
Page 81: ......
Page 82: ...Part Number 45W5353 Printed in USA GC27 2267 00 1P P N 45W5353 53 1001490 01...