Visually verify that the shelf ID for each SAS storage expansion unit is unique. If an ID is not unique, set
the ID:
1.
Remove the front bezel if you have not already removed it.
2.
Press and hold the shelf ID U-shaped tab (for EXN3000s) or button (for EXN3500s)
1
until the first
digit blinks.
3.
Press the tab or button until the correct number is displayed.
4.
Repeat steps 2 and 3 for the second digit.
5.
Press and hold the tab or button until the second number stops blinking.
Result:
Both numbers start blinking and the Fault LED on the operations panel illuminates after about
five seconds.
6.
Power-cycle the SAS storage expansion unit to make the new expansion unit ID take effect.
7.
Replace the front bezel.
Connecting the N6000 series filer to a network
Use these instructions to connect the N6000 series filer to a network.
Note:
For a dual-controller N6000 series filer, perform the steps in this section for each controller node of
the N series system.
1.
Refer to Figure 8 on page 9. Install the cable management tray
5
by pinching the arms of the tray
and fitting the holes in the arms over the retaining pins
1
under the controller cam handle
3
.
Then release the tray arms.
When the system is cabled in later steps, push the onboard and adapter cables
2
through the tray
clips
4
and secure them at the end with the hook-and-loop fastener.
1
exn350006
Figure 6. Shelf ID button on the EXN3500
Fibre
Channel
Ethernet
Console
Management
port
n600009
Figure 7. Port labels
8
Summary of Contents for 2858-A10
Page 4: ...iv...
Page 27: ......