B on the N6000 series system should be a Fibre Channel port used as an initiator port for attaching
disk storage expansion units, not a Fibre Channel port configured as an FCP target port.
v
If the FC IN port of controller B on the first disk storage expansion unit of the loop is attached to
controller B on the N6000 series system, then attach a fiber cable from the FC OUT port on lower
controller B of the last storage expansion unit (where you inserted the SFP GBIC in step 2 on page
15) to a Fibre Channel port on controller A on the N6000 series system. The Fibre Channel port on
controller A on the N6000 series system should be an FC port used as an initiator port for attaching
disk storage expansion units, not a Fibre Channel port configured as an FCP target port.
Installing the power cables
Use these instructions to install the power cables for the N6000 series filer.
1.
Make sure all power supply switches on the N6000 series filer and any attached expansion units are
in the Off position.
2.
Connect the power cords to all power supply unit (PSU1 and PSU2) power receptacles for all storage
systems that are being installed using power cord retainer clips as shown in Figure 12, making sure to
slide the clip all the way forward on the plug.
3.
Connect the power cords to the power sources, making sure that the two power supplies are
connected to separate AC sources. This ensures redundant power.
Attention:
Do not power on the system at this time.
Note:
The N6000 series filer has no requirement or provision for grounding.
For proper grounding of expansion units, see the
Installation and Setup Instructions
for the expansion
unit.
n620024
Figure 12. Using the power cord retention clip