v
No more than four expansion enclosures can be chained to port 2 (above the
control enclosure). The connecting sequence from port 2 of the node canister is
called chain 2.
v
No cable can be connected between a port on an upper canister and a port on a
lower canister.
v
Attach cables serially between enclosures; do not skip an enclosure.
v
The last enclosure in a chain must not have cables in port 2 of canister 1 and
port 2 of canister 2.
v
Ensure that cables are installed in a tidy manner to reduce the risk of cable
damage when Storwize V7000 Unified replaceable units are removed or inserted.
v
Arrange your cables to provide access to:
– The USB ports. Access is required to this port when you use the USB key to
configure the system.
– The enclosures themselves. Access is required to the hardware for servicing
and for safely removing and replacing components using two or more people.
v
Ensure that each SAS cable is fully inserted. A click is heard when the cable is
successfully inserted.
Note:
If you make a mistake during cabling and must unplug a SAS cable, pull
the blue tag to release the cable.
1.
Review Table 1 and the following figures before attaching the SAS cables.
Table 1. How to connect SAS cables to expansion units.
SAS Connections: How the first unit connects to the second unit
First Unit
Second Unit
Number of Expansions
Controller
Expansion 1
1 Expansions
Upper canister port 1
Upper canister port 1
Lower canister port 1
Lower canister port 1
Controller
Expansion 2
2 Expansions
Upper canister port 2
Upper canister port 1
Lower canister port 2
Lower canister port 1
Expansion 1
Expansion 3
3 Expansions
Upper canister port 2
Upper canister port 1
Lower canister port 2
Lower canister port 1
Expansion 2
Expansion 4
4 Expansions
Upper canister port 2
Upper canister port 1
Lower canister port 2
Lower canister port 1
Expansion 3
Expansion 5
5 Expansions
Upper canister port 2
Upper canister port 1
Lower canister port 2
Lower canister port 1
Expansion 4
Expansion 6
6 Expansions
Upper canister port 2
Upper canister port 1
Lower canister port 2
Lower canister port 1
Expansion 5
Expansion 7
7 Expansions
Upper canister port 2
Upper canister port 1
Lower canister port 2
Lower canister port 1
Chapter 2. Performing the hardware installation
25
Summary of Contents for 2073-700
Page 4: ...iv Storwize V7000 Unified Quick Installation Guide ...
Page 6: ...vi Storwize V7000 Unified Quick Installation Guide ...
Page 8: ...viii Storwize V7000 Unified Quick Installation Guide ...
Page 10: ...x Storwize V7000 Unified Quick Installation Guide ...
Page 22: ...12 Storwize V7000 Unified Quick Installation Guide ...
Page 70: ...60 Storwize V7000 Unified Quick Installation Guide ...
Page 80: ...70 Storwize V7000 Unified Quick Installation Guide ...
Page 81: ......
Page 82: ... Part Number 00L4661 Printed in USA GA32 1056 01 1P P N 00L4661 ...