DESCRIZIONE

MVE204 

MVE204S

MVE206 

MVE206S

MVE210 

MVE210S

MVE215 

MVE215S

MVE222 

MVE222S

Output U

Voltage 2-10 V DC (0-100%), max load 2 mA

Room temperature

Operation -10°C to 55°C; storage -20°C to 55°C

Room humidity

Max. 90% R.H.

Protection degree

IP54 (with PG13,5 cable gland - not supplied)

Insulation class

Standard

Emission/Immunity EMC 2014/30/UE according to EN 61326-1:2013 standard 

LVD 2014/35/UE according to EN61010-1 standard

Material

Housing: aluminium - cover: ABS plastic

Colour

Aluminium / white

Weight [kg]

1.7 (MVE2xx); 1.6 (MVE2xxS)

OPERATION

The actuator translates the control signal (modulating or 3 point floating) from the controller into a valve position. A modern brush-

less DC motor in the actuator drive a gear train and a worm gear – screw jack mechanism convert the motor revolutions into accurate 

and repeatable linear movements.

Control Signal

MVE2xx can be controlled by one of 2 main control types.

•  3 point floating;

•  modulating (or proportional) signal with field selectable range (e.g., 0-10 V DC, 2-10 V DC, 0-5/2-6V DC, 5-10/6-10 V DC and 4-20 

mA).

Manual Override

There is a manual operation handle on the actuator. When it is lowered (manual override ON), the power supply to the motor power 

stage circuitry is cut and the motor stops. The actuator can be operated manually and the valve positioned accordingly. The manual 

override lever latches in position until it is raised again, then board and motor will be powered again. At the end of this operation 

the actuator moves to initial position (on the basis of DIP n. 1 setting) then it follows the control signal. When the manual override is 

engaged the GREEN and the RED LED are ON.

Manual operation handle can also be used to modify any DIP switch setting or as re-set function after any alarm occurrence. The 

actuator is supplied with the manual override lowered (ON). It is not necessary to remove power supply to modify DIP switch setting, 

but, in this case, take care of 230Vac voltage.

Feedback Position

The actuator utilizes a 2-10 V position feedback (look at DIP n. 1 setting).

Calibration

The actuator has both auto and manual stroke calibration, DIP n. 7.

In factory delivery the auto stroke calibration is enabled – manual calibration is not necessary unless maintenance is required on the 

valve or certain alarm functions are desired.

End Point Auxiliary Switches (accessory DMVE)

End point switches change over when the valve is fully open or closed. They are free contact with 24V AC/DC, 4A max voltage to 

terminals.

End point switches can be utilized to indicate valve stroke end positions and for relay control of additional plant equipment. When 

the actuators are controlled individually or in sequence, it is possible to use the end switches to toggle when the valve is fully open 

or fully closed. The auxiliary switch position according to control signal (Y) is shown in the table below.

CONTROL SIGNAL (Y)

RELAY KC1

RELAY KC2

0-0,5 V DC

KC1 to K2

KC2 to K3

0,5-9,5 V DC

KC1 to K1

KC2 to K3

9,5-10 V DC

KC1 to K1

KC2 to K4

Summary of Contents for MVE2 Series

Page 1: ...and it is able to self calibrate on a different stroke without the need of any user action this function is DIP switch selectable on the field MVE2xx has intelligent behaviour and alarm functionality...

Page 2: ...ion until it is raised again then board and motor will be powered again At the end of this operation the actuator moves to initial position on the basis of DIP n 1 setting then it follows the control...

Page 3: ...ng accordingly see Diagnostic Alarm Function Table ASSEMBLING The actuator can be mounted with any orientation but never up side down When the fluid temperature exceed 120 C the actuator shall be moun...

Page 4: ...o H2 X S and H3 X S with AG82 with AG82 Siemens with AG70 10 with AG70 14 Danfoss VR VF S models with AG60 07 TAC DN15 V298 with AG60 08 TAC DN15 V2XX V3XX with AG60 09 Honeywell with AG60 10 Airtek w...

Page 5: ...m Y2 Close V 16 V DC Voltage Output max 25 mA AWG20 min 0 5mm2 max 1 5mm2 200 m M 0 V Common U 2 10 V DC Feedback Output Signal AWG20 min 0 5mm2 max 1 5mm2 200 m M 0 V Common Note To avoid damages to...

Page 6: ...3 Selection of sequence mode control range defined by DIP n 5 4 Modulating Control 0 10 V DC DIP n 2 OFF only Modulating Control 2 10 V DC DIP n 2 OFF only 5 Sequence Control 0 5 V DC with DIP n 4 OF...

Page 7: ...st the new stroke limit then it goes back to the initial position still signalling the anomaly until it is not within 60mm The actua tor does not calibrate the stroke after 10s wrong range Valve with...

Page 8: ...me point of the stroke read 2 GREEN BLINKING The actuator arrived at the intermediate point of the stroke read 3 RED GREEN BLINKING The actuator is reading the stroke or it is going to initial positio...

Reviews: