51
Version 18.01, 1-Mar-2018
11. Appendix
11.1 Information about IBC AeroFix
Tightening torques of screw connections
The tightening torques of the screw connections used in the IBC AeroFix flat roof system should be
dimensioned in accordance with DIN ISO 3506. Due to the difficulty in determining the friction coefficients
in the external area, dimensioning in accordance with DIN ISO 3506 can prove difficult. We therefore
recommend the following tightening torques:
Screw connection
Tightening torque
M8 (module clamp)
15 Nm
M8 (other)
10 Nm
Tab. 7: Tightenning torques
11.2 Maintenance instructions
The IBC AeroFix mounting system is largely maintenance-free thanks to the materials used.
In addition to the electrical inspections prescribed for the entire PV system, we recommend an annual and
event-dependent (heavy storm, hail etc.) inspections of the mounting system into account the points of the
maintenance log..
Disassemly of the mounting system is carried out in the reverse order of assemly steps.
If it becomes necessary to clean the modules, this must be done without chemical cleaning products and
using only clear water.
The modules can easily be replaced by removing the module cabling and releasing the corresponding
module clamps. Please observe the relevant safety requirements when doing this.
Summary of Contents for AeroFix 15-S
Page 1: ...1 Installation instructions IBC AeroFix Version 18 01 Date 1 Mar 2018...
Page 15: ...15 Version 18 01 1 Mar 2018 Fig 12 Installation base rails Fig 13 Installation base rails...
Page 40: ...40 Version 18 01 1 Mar 2018 Fig 58 Wind plate assembly Fig 59 Fixation wind plate...
Page 52: ...52 Version 18 01 1 Mar 2018...
Page 55: ...55 Version 18 01 1 Mar 2018 11 4 Checklist IBC AeroFix...
Page 56: ...56 Version 18 01 1 Mar 2018...