ibaPADU-8-M Manual
Issue 1.9
13
7.2.4
Terminal Blocks Pin Connections X14, X1, X5
Note: the counting order is from the top to the bottom.
Power Supply Connections X14
Pin
Connection
1 +24
V
2 0
V
Analog X1 and Binary Pin Connections X5
Pin
Analog
Connection
Digital
Connection
X1
X5
1
+ channel 0
BE00 +
2
- channel 0
BE00 -
3
+ channel 1
BE01 +
4
- channel 1
BE01 -
5
+ channel 2
BE02 +
6
- channel 2
BE02 -
7
+ channel 3
BE03 +
8
- channel 3
BE03 -
9
+ channel 4
BE04 +
10
- channel 4
BE04 -
11
+ channel 5
BE05 +
12
- channel 5
BE05 -
13
+ channel 6
BE06 +
14
- channel 6
BE06 -
15
+ channel 7
BE07 +
16
- channel 7
BE07 -
7.2.5
Run, Link and Error LED Indicators L1…L3
LED
Status
Indication
Run
(green)
Blinking
Off
power is on and device is healthy
no power
Link
(yellow)
Off
On
Blinking
No incoming data stream (PC is inactive or the previous device in
the chain is defective)
data is being received at RX (not active in multiplex mode)
bidirectional connection from the device to FOB-io (active in multi-
plex mode)
Error
(red)
On
Off
device error
device healthy, automatically resets when error condition ends