ibaPADU-8-ICP Manual
10.1.6
Control of ibaPADU-8-ICP in ibaLogic application program
In order to work with the ibaPADU-8-ICP, the device must be supplied with some con-
trol data from the application software. With ibaScope a part of the date is supplied
automatically.
When using the device with ibaLogic the required parameters must be evaluated in the
application and transferred to the device over the FOB-M output resources.
First, these are the values for gain and frequency for each channel to be used. The val-
ues depend on the measurement arrangement and sensor types.
For the supply of the other parameters iba developed a sample function block
FOBM_Control which is available from iba on request.
The use of this function block is described by means of a sample application (layout).
The inputs Run, Apply and F_Reset are set by the application and control the process-
ing, the takeover of new parameters and the resetting.
The application also evaluates the values for Data_Size, Set_PaduNumber,
Check_PaduNumber and SampleTime.
The input Data_Available is directly linked to the input resources (FOBM In Link 0 Data
Available).
Issue 1.7
29