Setting the VMEbus Start Address
The lower two DIP switches are used for setting the VME memory address of the card in
hex-code.
The assignment of DIP switch bits and address is shown in the picture below with start
address 0x77900000 as an example.
Figure 3
VME memory addressing
The lower four hex digits of the address have the value 0. There are no switches to
change these values. The bit A16 and A17 have the fixed value 0 too.
The address setting can be modified from the 19
th
bit (A18) on. Thus, the value of the 5
th
hex digit can be 0, 4, 8 or C.