© 2008 I&J Fisnar Inc.
3.5 Initial Output Port
Initial Output Port
sets the ON/OFF status of the output signals at the start of each
program cycle.
Initial Output Port
value is the decimal representation of an 8 binary bit values controlling
the 8 output signals.
For example,
Output Status
(X = on, blank = OFF)
Decimal
Value
#1 #2 #3 #4 #5 #6 #7 #8
0
1
X
2
X
4 X
8
X
16 X
32 X
64 X
128 X
3.6 Debug Speed (mm/s)
Debug Speed allows the debug speed to be set. This speed is the speed at which the tip
will move when running in Debug mode. See also
SECTION 5:5.6 Debug Program
3.7 Utility
Menu
.
3.8 Jog
Speed
The Jog Speed setting allows the user to select the jog speed for programming in Teach
mode. The Jog speed can be set to Low, Middle or High speed.
The default value is
2. Middle
.